Specifications

Six size channels

0.3 µm, 0.5 µm, 1.0 µm, 2.0 µm, 5.0 µm, 10.0 µm

Flow rate

0.1 cfm (2.83 L/min)

Light source

775 nm to 795 nm, 90mW class 3B laser

Count modes

Raw counts, #/m

3

, #/ft

3

, #/liter in Cumulative or Differential mode

Counting efficiency

50 % @ 0.3 µm; 100 % for particles > 0.45 µm (per ISO 21501)

Zero count

1 count/5 minute (JIS B9921)

Concentration limits

10 % at 4,000,000 particles per ft

3

(per ISO 21501)

Data storage

10,000 records (rotating buffer)

Alarms

User selected particle channels and limits

Display

QVGA color with backlight

Delay time

0 to 24 hours

Sample inlet

Isokinetic probe

Security

Administrator password controlled (optional)

Communication mode

USB or Ethernet

Dimensions (L x W x D)

27.2 cm x 9.9 cm x 5.3 cm (10.7 in x 3.9 in x 2.1 in)

Weight

0.68 kg (1.5 lb)

Power adapter

100 V ac to 240 V ac, 12 V dc, 2.5 A

Rechargeable battery

Li-ion 7.4 V 2600 mAh

Battery duration/charge time

10 hours typical use (5 hours continuous sampling)/3.5 hours

Calibration

PSL particles in air (NIST traceable)

Operating environment

50 °F to 104 °F (10 °C to 40 °C)/< 95 % non-condensing relative humidity

Storage environment

14 °F to 122 °F (-10 °C to 50 °C)/Up to 98 % non-condensing relative humidity

Warranty

One-year

Accessories included

Cradle for charging and convenient USB and Ethernet communications, Ethernet cable, USB cable,

12 V dc power supply, zero count inlet-filter, filter adapter, sample inlet protective cap, hard case,

getting started manual and users manual CD

2 Fluke Corporation Fluke 985 Particle Counter

Fluke Corporation

PO Box 9090, Everett, WA 98206 U.S.A.
Fluke Europe B.V.

PO Box 1186, 5602 BD

Eindhoven, The Netherlands
For more information call:

In the U.S.A. (800) 443-5853 or

Fax (425) 446-5116

In Europe/M-East/Africa +31 (0) 40 2675 200 or

Fax +31 (0) 40 2675 222

In Canada (800)-36-FLUKE or

Fax (905) 890-6866

From other countries +1 (425) 446-5500 or

Fax +1 (425) 446-5116

Web access: http://www.fluke.com

©2012 Fluke Corporation.

Specifications subject to change without notice.

Printed in U.S.A. 3/2012 4148253A D-EN-N

Modification of this document is not permitted

without written permission from Fluke Corporation.

Fluke.

Keeping your world

up and running.

®

Other IAQ tools from Fluke

Ordering information

Fluke-985

Airborne Particle Counter

Fluke-CO-205 Aspirator Kit

Fluke-CO-220 Carbon Monoxide Meter

Fluke-922

Airflow Meter

Fluke-971

Temperature Humidity Meter

Fluke-975 AirMeter™

CO-205 Aspirator Kit for flue gas

sampling using Fluke family of gas

measuring devices.
CO-220 Carbon Monoxide Meter

measures CO levels in industrial

environments, commercial or residential

buildings where accumulation of

combustion gas is possible.
Fluke 922 Airflow Meter makes airflow

measurements easy by combining

differential pressure, airflow, and velocity

into a single, rugged meter.
Fluke 971 Temperature Humidity Meter

takes accurate humidity and temperature

readings in the air for maintaining

optimal comfort levels and good indoor

air quality for facility maintenance and

utility technicians, and HVAC-service

contractors.
Fluke 975 AirMeter

combines 5

powerful air quality tools into one for

measuring essential IAQ parameters:

temperature, humidity, dew point and wet

bulb temperature, air volume, air velocity,

CO, CO2, and % of outdoor air calculation.