Technical data, Electrical, Portaflow 220 technical datasheet – Atec Micronics-PF220 User Manual
Page 6: Technical data electrical
Portaflow 220 Technical Datasheet
6
Portaflow 220 Technical Datasheet
(Issue 1.0)
Technical data
Electrical
General specification:
DSP measurement technique –
The PF220 uses ‘transit time’ measurement with a sampling resolution of 50 pico-
second, with a continuous signal level indication to the display
Flow velocity range (bi-directional) –
• Minimum velocity 0.1m/s
• Max velocity 20m/s
Flow measurement accuracy –
• ±0.5% to ±2% of flow reading for flow rate >0.2m/s and Pipe ID >75mm
• ±3% of flow reading for flow rate >0.2m/s and Pipe ID in range 13mm - 75mm
• ±6% of flow reading for flow rate < 0.2m/s
•
Flow velocity corrected for Reynolds number over entire velocity range
Repeatability –
• ±0.5% of measured value or ±0.02m/s whichever is the greater
Response time –
• < 500ms depending on pipe diameter
Selectable flow units –
• VELOCITY: m/sec, ft/sec
• VOLUME: l/s, l/min, l/h, gal/min, gal/h, USgals/min, USgals/h, Barrel/h,
Barrel/day, m³/s, m³/min, m³/h
Selectable volume units –
• l, gal, USgals, Barrel, m³
Total volume –
• 12 Digits - forward and reverse
Display languages –
The following operator languages can be selected from the PF220 set-up menu
• English
• French
• German
• Italian
• Spanish
• Portuguese
• Russian
• Norwegian
• Dutch
Supply voltage:
Power supply charger:
Input voltage range
–
9–24Vdc
Manufacturer –
Model ECO-181WP12
Power consumption
–
10.5W
Input voltage range –
90–264Vac
Battery:
Input frequency range –
47–63Hz
Technology –
5-cell NiMH
Output voltage –
12Vdc
Capacity –
3.8AHr
Max. Output current –
1.5A
Operating time –
Typically 20 hours continuous with
backlight and 4-20mA output OFF
Approvals –
UL, CUL, TUV, CB & CE
Recharge time –
6.5 Hours
Service life –
>500 charge/discharge cycles