Frequency Range

50/60 Hz

System interface

RS-232/485

Connector

DB9

User port

Two function:
HD- Interlock
Key

Display

4 lines LCD 20 characters

Power supply AC

230 VAC 10%,

Max current

16 A

Output voltage Without load

Max 4Vac

Output current Max continuos

170 A

Output current Max short

1200 A

Internal timer Continuous mode

1-12000 min.

Internal timer Short mode

1-5 sec.

Timer resolution Continuous mode 1 min

Timer resolution Short mode

1 sec.

Size Generator

365 x 200 x 480 mm (WxHxD)

Size Loop

1030 x 35 x 1030 mm (WxHxD)

Size Truck

550 x 210 x 650 mm (WxHxD)

Size Mast antenna

1900 mm (H)

Size Cables

95 mm

2

1.5 mm

Weight Generator

28 Kg

Weight Loop

6 Kg

Weight Truck

25 Kg

Specifications

Narda Safety Test Solutions srl

Via Leonardo da Vinci, 21/23
20090 Segrate (MI) ITALY
Phone: +39 02 26 998 71
Fax: +39 02 26 998 700
E-Mail: [email protected]
www.narda-sts.it

PMM 1008

MAGNETIC FIELD GENERATOR