Nemp radiated susceptibility test setup

background image

montena technology - 1728 Rossens - Switzerland - phone + 41 26 411 84 84 - fax + 41 26 411 17 79

www.montena.com

e-mail: [email protected]

NEMP radiated susceptibility test setup

This test set-up can be used for the susceptibility testing of small pieces of equipment such as
printed boards, small subsystems, etc., according to MIL-STD-461 / RS105 (NEMP: nuclear
electromagnetic pulse). Associated with the generator EMP25K-2-23, the minimum field under
the line RL50-50 is 50 kV/m at full output. Even higher fields can be achieved for smaller
objects placed close to the beginning of the line. The line can also be used for other pulse or
CW tests.

The antenna is fixed on a stable and solid table which can be moved easily. The generator can
be controlled by a computer through RS232 and USB interface. We also provide all the
necessary accessories like electromagnetic field sensors, interconnecting cables, voltage
dividers for the measurement of the output of the generator, etc.

SPECIFICATIONS - Generator

Type

EMP25K-2-23

Standard

MIL-STD461-E / F, paragraph RS105

Peak voltage

typically ≤ +0.2 kV to ≥ +25 kV

Impedance

100 ohm

Rise time (10 – 90 %)

2.3 ns ± 0.5 ns

Pulse length on 100 ohm (50 – 50 %)

23 ns ± 5 ns

Output connector

HVM50K

Power rating

85 - 264 V

ac

/ 50 - 60 Hz / 150 VA

Dimensions

56 x 19 x 45 cm (L x H x W)

Weight

15 kg

SPECIFICATIONS - Line

Type

RL50-50

Structure

bounded wave line / TEM mode

Impedance

100 ohm

Maximum height of the EUT

17 cm (according to MIL-STD461 / RS105)

Input connector

HVM50K

Dimensions

200 x 55 x 80 cm (L x H x W)

Weight

25 kg