MODEL 7399-2 SPIKE GENERATOR
USEFUL ACCESSORIES
(Not Included)
Type 6220-1A Transformer. Can be used as a
high current series inductor.
Type 7032-1 Isolation Transformer. For remov-
ing power ground from the case of the scope (see
diagram above).
TEST CIRCUIT FOR APPLICATION OF LINE-TO-LINE HIGH VOLTAGE SPIKES TO NAVY EQUIPMENT
SUPPLIED BY SINGLE PHASE A.C. POWER. REF.: MIL-STD-1300, APPENDIX B.
SPECIFICATIONS
NO LOAD
0.5 OHM LOAD
Peak Amplitude:
100-2500 V
100-2000 V
Rise Time:
≈
1
ȖS
≈
2
ȖS
Duration to
50% of Peak:
≈
50
ȖS
≈
31
ȖS
Duration to
Zero Crossover:
≈
100
ȖS
≈
77
ȖS
Repetition Rate: 2 pulses per minute.
Phase Adjustment: Spike position adjustable
from 0
ᑻ to 360ᑻ on 50, 60 or 400 Hz sine wave.
Internal Impedance: Less than 0.1 ohm.
Peak Output Power: 8 Megawatts into 0.5 ohm
load.
Power Current in Series Injection Mode:
Handles up to 100 amperes of current at power
frequencies.
Power Requirements: 115 volts 60 Hz, 2.0
amperes (230 volts 50 Hz, 1.0 ampere available).
Size: 21.06" wide, 12.56" high, 15.50" deep
(53.5 cm x 31.9 cm x 39.4 cm).
Weight: 70 pounds plus 5 pounds for accessories.
Total Shipping Weight: 75 pounds.
* Spike duration can be changed from
≈
20
ȖS to
≈
100
ȖS using internal jumpers.
ACCESSORIES
(Supplied)
P/N 739945 Plug-in Unit for series injection of
spike into power lines.
P/N 739950 Plug-in Unit for parallel injection
(using external components).
Mating connectors: Two 100 ampere styles, for
power connections; two 50 ampere styles, for
external resistor.