beautypg.com

Atec Solar-7399-2 User Manual

Page 2

background image

MODEL 7399-2 SPIKE GENERATOR

USEFUL ACCESSORIES

(Not Included)

Type 6220-1A Transformer. Can be used as a
high current series inductor.

Type 7032-1 Isolation Transformer. For remov-
ing power ground from the case of the scope (see
diagram above).

TEST CIRCUIT FOR APPLICATION OF LINE-TO-LINE HIGH VOLTAGE SPIKES TO NAVY EQUIPMENT

SUPPLIED BY SINGLE PHASE A.C. POWER. REF.: MIL-STD-1300, APPENDIX B.

SPECIFICATIONS

NO LOAD

0.5 OHM LOAD

Peak Amplitude:

100-2500 V

100-2000 V

Rise Time:

1

ȖS

2

ȖS

Duration to
50% of Peak:

50

ȖS

31

ȖS

Duration to
Zero Crossover:

100

ȖS

77

ȖS

Repetition Rate: 2 pulses per minute.

Phase Adjustment: Spike position adjustable
from 0

ᑻ to 360ᑻ on 50, 60 or 400 Hz sine wave.

Internal Impedance: Less than 0.1 ohm.

Peak Output Power: 8 Megawatts into 0.5 ohm
load.

Power Current in Series Injection Mode:
Handles up to 100 amperes of current at power
frequencies.

Power Requirements: 115 volts 60 Hz, 2.0
amperes (230 volts 50 Hz, 1.0 ampere available).

Size: 21.06" wide, 12.56" high, 15.50" deep
(53.5 cm x 31.9 cm x 39.4 cm).

Weight: 70 pounds plus 5 pounds for accessories.

Total Shipping Weight: 75 pounds.

* Spike duration can be changed from

20

ȖS to

100

ȖS using internal jumpers.

ACCESSORIES

(Supplied)

P/N 739945 Plug-in Unit for series injection of
spike into power lines.

P/N 739950 Plug-in Unit for parallel injection
(using external components).

Mating connectors: Two 100 ampere styles, for
power connections; two 50 ampere styles, for
external resistor.