L3-100, Related products, Ordering information – Atec PMM-L3-100 User Manual
Page 2: Optional accessories, L3-100 equivalent circuit
L3-100
Three phase plus neutral V-Network 9 kHz - 30 MHz
125 A for AC and DC powered EUT
Narda Safety Test Solutions Srl
Via Leonardo da Vinci, 21/23
20090 Segrate (Milano) - ITALY
Phone: +39 02 2699871
Fax: +39 02 26998700
E-Mail: [email protected]
Internet: www.narda-sts.it
L3100-FEN-30400 - Specifications subject to changes without prior notice
•
Electrical safety and presence
of ground protection relays do
require the installation of properly
rated insulating transformer(s)
between mains power line and
AMN line inputs.
•
High mains noise may require
the installation of properly rated
mains filters to reduce the level of
unwanted signals.
9 kHz - 30 MHz
100 A continuous
125 A for 5 minutes
230 VAC; 325 VDC
400 VAC; 565 VDC
DC - 60 Hz
50 Ω // [5 Ω + 50 µH]
with 250 µH choke
BNC female
125 A plug and socket outlet
according to IEC309 standard
-10 °C to +40 °C
-25 °C to +75 °C
465 x 450 x 740 mm
70 kg
100 kg
SPECIFICATIONS
Frequency range
Max. continuous rated
output current
Overload current
Max. operating voltage (L/PE) (N/PE)
(L/L) (L/N)
Input mains frequency range
Equivalent circuit
RF output connector
EUT connection
Operating temperature
Storage temperature
Overall Dimensions mm (W x H x D)
Weight
Gross weight
Receivers
LISN
RFI Filters
• 7010: EMI receiver 150 kHz -1 GHz
• 9010: EMI receiver 10 Hz - 30 MHz
• 9010F: EMI receiver 10 Hz - 30 MHz
• 9010/03P: EMI receiver 10 Hz - 300 MHz
• 9010/30P: EMI receiver 10 Hz - 3 GHz
• 9010/60P: EMI receiver 10 Hz - 6 GHz
• L2-16B: single phase AMN, 16 A
• L3-32: 4 lines, 3-phase AMN, 32 A
• L3-64: 4 lines, 3-phase AMN, 64 A
• L3-64/690 4 lines, 3-phase AMN, 64A/690V
• L3-500: 4 lines, 3-phase AMN, 350 A
• L1-150M: single-path, 50 Ohm etc AMN 150 A
• L1-500 Single phase AMN, 500A
• L2-D: Delta LISN for telecom, 2 A, 150 Ω
• FIL-L2-16F: single phase RFI filter, 16 A
• FIL-L2-24M: single phase RFI filter, 24 A
• FIL-L3-32M: 3-phase+neutral RFI filter, 32 A
• FIL-L3-70M: 3-phase+neutral RFI filter, 70 A
Ordering Information:
L3-100 3-phase Artificial Mains Network
Includes: IEC mains plug, RF cable, LISN remote control
cable, user’s manual, calibration certificate.
Optional accessories:
LISN service kit
(AC-BNC adapter for LISN verification and calibration)
Related Products
L3-100 equivalent circuit