beautypg.com

Atec Fischer Custom Comm_F-72 User Manual

F-72 current probe

background image




The F-72 has a usable frequency range of 100 Hz to
100 MHz. It has a transfer impedance of 5

 from 500

kHz to 100 MHz. This probe can be used to measure
small RF currents in the basic configuration and pulse
currents with wide ranging magnitudes in the other
variations of this current probe.

F-72

Current Probe

Fischer Custom Communications, Inc.

F-72 Specifications

Frequency: 100 Hz – 100 MHz

Connector: Type-N

Internal diameter:

67mm DC to 60 Hz: 350 amperes

External diameter: 142mm

400 MHz: 350

amperes

Height:

53mm RF(CW): 100

amperes

Z

t

:

5

Pulse

2

: 100

amperes

dB





Probe calibrated with 50+j0 Load Impedance

2:

Depends

upon

the

pulse width and pulse rep. Rate.

20603 Earl St., Torrance, CA 90503 · Phone: 310-303-3300 Fax 310-371-6268 · email: [email protected]

 Fischer Custom Communications, Inc.

072803DS-F-72

All rights reserved

 Printed in USA

-55

-50

-45

-40

-35

-30

-25

-20

-15

-10

-5

0

5

10

15

20

100Hz

1kHz

10kHz

100kHz

1M Hz

10M Hz

100M Hz

Frequency

Tran

fer Imp

e

dance (dBo

hms)