Attenuators fixed – Atec Narda-700 Series User Manual
Page 4
Type N (M/F) DC to 11 GHz, 20 Watt - 50 Watt
Features
▪ Designed to Meet Environmental
Requirements of MIL-A-3933
Models
▪ 768-3, 768-6, 768-10, 768-20, 768-30
Model
768-3
768-6
768-10
768-20
768-30
Low Frequency (GHz)
DC
DC
DC
DC
DC
High Frequency (GHz)
11.0
11.0
11.0
11.0
11.0
Attenuation dB (Nominal)
3
6
10
20
30
Attenuation dB (Deviation DC-3)
+/-0.25
+/-0.25
+/-0.25
+/-0.25
+/-0.25
Attenuation dB (Deviation 3-6)
+/-0.50
+/-0.50
+/-0.50
+/-0.50
+/-0.50
Attenuation dB (Deviation 6-11)
+/-0.75
+/-0.75
+/-0.75
+/-0.75
+/-0.75
Power Input (Max Avg.) in W
20
20
20
20
20
Power Input (Max Peak) in kW
1
1
1
1
1
VSWR (max) DC-1 GHz
1.10
1.10
1.10
1.10
1.10
VSWR (max) 1-4 GHz
1.15
1.15
1.15
1.15
1.15
VSWR (max) 4-6 GHz
1.20
1.20
1.20
1.20
1.20
VSWR (max) 6-11 GHz
1.30
1.30
1.30
1.30
1.35
Maximum Weight (gr)
159
159
159
159
159
Maximum Weight (oz)
5.6
5.6
5.6
5.6
5.6
Special Notes:
A , B , C
A , B , C
A , B , C
A , B , C
A , B , C
Special Notes:
A: Power ratings for horizontal operation at + 25°C derate linearly to 5 watts at + 125°C
B: Temperature Coefficient: 0.0006 dB/dB/°C; Power Coefficient: 0.0005 dB/dB/watt.
C: Ordering information: Specify model number and add dash number suffix for attenuation in dB. For example: 776C-10.
Attenuators Fixed
Adapters
Attenuators
Couplers
DC
Blocks Detectors
Isolators &
Circulators
Phase
Shifters
Power Dividers and
Hybrids
Terminations (50 Ohm
Loads)
Waveguide
435 Moreland Road • Hauppauge, New York 11788
TEL: (631) 231-1700 • FAX: (631) 231-1711
www.nardamicrowave.com • EMAIL: [email protected]
71