Type N (M/F) DC to 11 GHz, 20 Watt - 50 Watt

Features

▪ Designed to Meet Environmental

Requirements of MIL-A-3933

Models

▪ 768-3, 768-6, 768-10, 768-20, 768-30

Model

768-3

768-6

768-10

768-20

768-30

Low Frequency (GHz)

DC

DC

DC

DC

DC

High Frequency (GHz)

11.0

11.0

11.0

11.0

11.0

Attenuation dB (Nominal)

3

6

10

20

30

Attenuation dB (Deviation DC-3)

+/-0.25

+/-0.25

+/-0.25

+/-0.25

+/-0.25

Attenuation dB (Deviation 3-6)

+/-0.50

+/-0.50

+/-0.50

+/-0.50

+/-0.50

Attenuation dB (Deviation 6-11)

+/-0.75

+/-0.75

+/-0.75

+/-0.75

+/-0.75

Power Input (Max Avg.) in W

20

20

20

20

20

Power Input (Max Peak) in kW

1

1

1

1

1

VSWR (max) DC-1 GHz

1.10

1.10

1.10

1.10

1.10

VSWR (max) 1-4 GHz

1.15

1.15

1.15

1.15

1.15

VSWR (max) 4-6 GHz

1.20

1.20

1.20

1.20

1.20

VSWR (max) 6-11 GHz

1.30

1.30

1.30

1.30

1.35

Maximum Weight (gr)

159

159

159

159

159

Maximum Weight (oz)

5.6

5.6

5.6

5.6

5.6

Special Notes:

A , B , C

A , B , C

A , B , C

A , B , C

A , B , C

Special Notes:

A: Power ratings for horizontal operation at + 25°C derate linearly to 5 watts at + 125°C

B: Temperature Coefficient: 0.0006 dB/dB/°C; Power Coefficient: 0.0005 dB/dB/watt.

C: Ordering information: Specify model number and add dash number suffix for attenuation in dB. For example: 776C-10.

Attenuators Fixed

Adapters

Attenuators

Couplers

DC

Blocks Detectors

Isolators &

Circulators

Phase

Shifters

Power Dividers and

Hybrids

Terminations (50 Ohm

Loads)

Waveguide

435 Moreland Road • Hauppauge, New York 11788

TEL: (631) 231-1700 • FAX: (631) 231-1711

www.nardamicrowave.com • EMAIL: [email protected]