beautypg.com

Atec Megger-220072 User Manual

Page 3

background image

70-, 120- and 160-kV DC

High Voltage DC Dielectric Test Sets

Ripple

Less than 2% on capacitive samples at continuous rated output

Temperature Range

Operating: -20 to +130° F (-30 to +55° C)
Storage: -40 to +150° F (-40 to +65° C)

Relative Humidity Range

Operating: 0 to 90% noncondensing
Storage: 0 to 95% noncondensing

Dimensions

Control Unit (all models)
20 H x 12 W x 12.5 D in.
(510 H x 305 W x 318 D mm)

High Voltage Unit
70 kV:

20 H x 12 W x 12 D in. (510 H x 305 W x 305 D mm)

120 kV:

29 H x 12 W x 12 D in. (740 H x 305 W x 305 D mm)

160 kV:

39 H x 12 W x 12 D in. (1000 H x 305 W x 305 D mm)

Weight

Control Unit (all models)
23 lb (10.5 kg)

High-Voltage Unit
70 kV:
44 lb (20 kg)
120 kV: 65 lb (30 kg)
160 kV: 73 lb (33 kg)

Cables (including carrying bag)
70 kV Models:
7 lb (3 kg)
120 and 160 kV Models: 9 lb (4 kg)

ADDITIONAL SPECIFICATIONS

OPTIONS AND ACCESSORIES

External Voltage Stabilizer

Filters input power to the test set and guards against line
voltage fluctuations that may cause inaccurate readings.

Strip Chart Recorder

Document and print test sample leakage current
measurements at the test site. This portable analog chart
recorder features two ranges (50 and 500 mA), with
results printed on pressure-sensitive paper.
Dimensions:
9 H x 7.5 W x 7.4 D in. (230 H x 190 W x 190 D mm)
Weight: 6 lb (2.7 kg)

Special Cable Lengths

For a nominal charge, a custom-length, shielded, high-
voltage output cable up to 50 ft (15 m) can be supplied.
Specify length when ordering.

High-voltage Discharge and Grounding Stick,
ratings 70/120/160 kV

Applications Guide

A practical guide, “Lowdown on HV DC Testing,” gives the
what, when, how and why of high-voltage dc testing and
its applications.

High-Voltage Discharge and Grounding Stick

Applying a suitably rated high-voltage resistance discharge
stick following a test is recommended. This is not only a
good safety practice, but will hasten discharge of highly
capacitive samples.

High-Voltage Discharge and Grounding Stick Specifications

Max. Safe

Voltage

Cat. No.

Resistance

Discharge Capacitance*

Length

Weight

70 kV

222070-62

90 MΩ

10 µF

51 in. (1.295 m)

2.0 lb. (0.9 kg)

120 kV

222120-62

100 MΩ

2.75 µF

51 in. (1.295 m)

2.7 lb. (1.2 kg)

160 kV

222160-62

120 MΩ

2.25 µF

71 in. (1.803 m)

3.3 lb. (1.5 kg)

*25ºC 15 minute cooling period required after discharge