TXL830, TXL850 and TXL870

Extra load units for TORKEL test system

APPLICATIONS


SPECIFICATIONS


Specifications are valid at nominal input voltage and an ambient
temperature of +25°C, (77°F). Specifications are subject to change
without notice.
Environment
Application field The instrument is intended for use in high-voltage
substations and industrial environments.

Temperature Operating

0°C to +40°C

Storage & transport

-40°C to +70°C

Humidity

5% – 95% RH, non-condensing

CE-marking
LVD 2006/95/EC
EMC 2004/108/EC




General
Mains voltage

100 – 240 V AC, 50 / 60 Hz

Power consumption

75 W (max)

Protection

Thermal cut-outs, automatic overload protection


Dimensions
Instrument

210 x 353 x 600 mm

Transport case

265 x 460 x 750 mm

Weight

13 kg
21.4 kg with transport case

Cable sets
for TXL830 and TXL 850 2 x 3 m, 70 mm

2

, 270 A, with cable

lug. Max. 100 V. 5 kg

for TXL870

2 x 3 m, 25 mm

2

, 110 A, with cable lug.

Max. 480 V. 3 kg

Load Section

TXL830 TXL850 TXL870

Max. voltage d.c.

28 V

56 V

140 V / 280 V

Max. current

300 A

300 A

112 A at 140 V

56 A at 280 V

Max. power

8.3 kW

16.4 kW

15.8 kW

Internal resistance, 3-position selector
Position 1

0.275

W 0.55

W 4.95

W

Current 100 A

at 27.6 V (12 x 2.3 V)

at 55.2 V (24 x 2.3 V)

-

78.5 A

at 21.6 V (12 x 1.8 V)

at 43.2 V (24 x 1.8 V)

-

50.1 A

-

-

at 248.4 V (108 x 2.3 V)

39.2 A

-

-

at 194.4 V (108 x 1.8 V)

Position 2

0.138

W 0.275

W 2.48

W

Current 200 A

at 27.6 V

at 55.2 V (24 x 2.3 V)

-

156 A

at 21.6 V

43.2 V (24 x 1.8 V)

-

Position 3

0.092

W 0.184

W 1.24

W

Current 300 A

at 27.6 V

at 55.2 V (24 x 2.3 V)

-

235 A

at 21.6 V

43.2 V (24 x 1.8 V)

-

100 A

-

-

at 124.2 V (54 x 2.3 V)

78.4 A

-

-

at 97.2 V (54 x 1.8 V)