background image

300 Series

Panel Detail

INPUT VOLTAGE

MODEL

MAXIMUM*
OUTPUT VOLTAGE

VOLTMETER RANGE

OUTPUT CURRENT
METER RANGE

METERS

OVERLOAD
SENSITIVITY

MEGOHM RANGES
(at 500 V dc):

Multiplier Position
M

Range

TERMINATIONS

DIMENSIONS

WEIGHT

SPECIFICATIONS

Model number suffix -A

120 V / 60 Hz

Model number suffix -B

220 V / 50 Hz

H306B

5.0 kV ac

6.0 kV dc

0-1.2/6 kV

0-5 mA ac, 0-0.5/5/50/500/5000

µ

A dc

4

1

2

" meter,

±

2% full scale accuracy

Adjustable from 0.5 mA to 5.5 mA

X 0.1

X 1

X 10

X10

2

X 10

3

0.1 to 10

1 to 100

10 to 1000

100 to 10,000

1,000 to 100,000

High voltage lead - 5 ft. long shielded high voltage test lead (RG58/U) with alligator clip.
Ground lead - 5 ft. long insulated test lead with alligator clip.

21" W x 20" D x 11" H (53 x 51 x 28 cm)

49 lb (22 kg)

59 lb (27 kg)

Net

Ship.

ACCESSORIES

• Safety Test Cage -The interlocked test cage door shuts off high voltage if the door

opens. Catalog No. TC-25

• Retractable Test Probe -The spring loaded, pistol–like probe exposes high voltage

only when the voltage is to be applied to the object under test. Catalog No. HTP-R

• Fixed Test Probe -Allows easy application of the high voltage to the object under

test. Catalog No. HTP-F

• Spare Parts Kit -Catalog No. SPK1-H301B, SPK1-H306B

*DC output voltage is negative with respect to ground.

DECEMBER 2000

H300B-DS-2

NOTE: Because Hipotronics has a policy of continuous product improvement, it reserves the right to change design and specifications without notice.

H301B

1.0 kV ac

1.5 kV dc

0-.75/1.5 kV

For further information, contact:

Hipotronics, Inc.

A Subsidiary of Hubbell, Incorporated

Route 22, P. O. Box 414

Brewster, NY 10509, U.S.A.

1-800-727-4476

Tel: 845-279-8091

Fax: 845-279-2467

Website: www.hipotronics.com

E-mail: [email protected]