Portable ac hipot test sets, Advantages, Pft model specifications – Atec High-Voltage-PFT Series User Manual
Page 2
HIGH VOLTAGE, INC.
31 County Rt. 7A • Copake, NY 12516 • (518) 329-3275 • Fax: (518) 329-3271
E-Mail: [email protected] •
Web: www.hvinc.com
High Voltage, Inc. designs and manufactures high voltage test equipment for utility and industrial applications. Also available are Very Low
Frequency (VLF) high voltage AC test sets, oil dielectric test sets, AC and DC instrumented test sets, cable fault locators and other products.
Revised 10/18/07
Input
HV Output
PFT Model Specifications
Advantages
PFT-103CM
PFT-303CM
PFT-503CM
PFT-1003CM
120 V, 60 Hz, 15A, or 230 V, 50/60 Hz, 8A
0-10 kVac, 1kVA resistive load
3 kVA capacitive load
Up to 300 mA current
0-100 kVac, 1 kVA resistive load
3 kVA capacitive load
Up to 30 mA current
0-50 kVac, 1kVA resistive load
3 kVA capacitive load
Up to 60 mA current
0-30 kVac, 1kVA resistive load
3 kVA capacitive load
Up to 100 mA current
20 ft. (6m) long shielded output cable
with alligator clamp and hook for test connections
3kVA: 1 hour ON, 1 hour OFF
1kVA: continuous
<5%
2% F.S.
3.5 inch
Scaled 0-5/10 kVac
3.5 inch
Scaled 0-50/100 kVac
3.5 inch
Scaled 0-25/50 kVac
3.5 inch
Scaled 0-12/30 kVac
3.5 inch
Scaled 0-40 mAac
3.5 inch
Scaled 0-1.0
mAac
, with x1, x10, x100 Range Multiplier
Top Toroid
(No output cable)
21È w x 11.25È d x 15.25È h
533 mm w x 286 mm d x 387 mm h
High Voltage Tank included in controls
13È w x 13È d x 22È h
330 mm w x 330 mm d x 559 mm h
62 lbs. (28kg)
75 lbs. (34kg)
75 lbs. (34kg)
Control–35 lbs. (16kg)
HV Tank–85 lbs. (39kg)
Models below 100 kVac are single piece units with a shielded cable output for fast and easy test setup. The
PFT-103CM, PFT-303CM, PFT-503CM, and PFT-1003CM are compensated enabling testing of 3 kVA loads with a
power draw of 1.5 kVA and operate from a conventional electrical source*. In addition, these units include a dual range
kilovolt meter, triple range output current meter and a guard/ground return mode enabling the operator to measure the
total current to ground or only the current flowing through the sample under test.
Portable AC Hipot Test Sets
Note: For 230 volt line input, an F is suffixed to the model number.
PFT-301CM
0-30 kVac, 1kVA resistive load
33 mA current
120V, 60 Hz, 10A
or 230V, 50/60 Hz, 5A
1kVA, 1 hour ON,
1 hour OFF
700VA: continuous
3.5 inch
Scaled 0-30 kVac
3.5 inch
Scaled 0-3.0 mAac
with x1, x10 x100 Range
Multiplier
17È w x 11.5È d x 14È h
431 mm w x 292 mm d
x 365 mm h
45 lbs. (20kg)
PFT-301CM Control Layout
PFT-503CM Control Layout
*3 kVA output power is only available with a capacitive load sized to draw 3 kVA at full rated output.
Available output current decreases with other loads.
at full output voltage in ground
mode but not guard mode
Output
Termination
Duty
Distortion
Meter Accuracy
Kilovolt Meter
Current Meter
Control
Dimensions
H.V. Tank
Dimensions
Weight
2.5 mA
1.0 mA
14 mA
20 mA
2.0 mA
No Load Current: