Mpp2000, Ordering information – Atec Megger-MPP2000 User Manual
Page 2

MPP2000
Megger Pinpointer
ISO STATEMENT
Registered to ISO 9001:2000 Reg. No. Q 09250
Registered to ISO 14001 Reg. No. EMS 61597
MPP2000_DS_US_V01
www.megger.com
Megger is a registered trademark.
Specifications subject to change
without notice.
Item (Qty)
Cat. No.
MPP2000 Pinpointer
Included Accessories
Ground microphone
1001-809
Behind-the-head headphones
90003-250
Carry strap
6220-780
MPP2000 (complete) Carry Case
2002-119
“AA” battery (8 required)
23415
Instruction manual MPP2000
81395
Optional Accessory
Noise-cancelling headphones
36162
ORDERING INFORMATION
UK
Archcliffe Road, Dover
CT17 9EN England
T +44 (0) 1 304 502101
F +44 (0) 1 304 207342
[email protected]
UNITED STATES
4271 Bronze Way
Dallas, TX 75237-1019 USA
T 1 800 723 2861 (USA only)
T +1 214 333 3201
F +1 214 331 7399
[email protected]
OTHER TECHNICAL SALES OFFICES
Valley Forge USA, College Station USA,
Täby SWEDEN, Sydney AUSTRALIA,
Ontario CANADA, Trappes FRANCE,
Oberursel GERMANY, Mumbai INDIA,
Johannesburg SOUTH AFRICA, Aargau
SWITZERLAND, Chonburi THAILAND,
and Dubai UAE
Noise Canceling Acoustic Filters
Digital: (3) HPF, (1) BPF, none
Acoustic Bands
120Hz to 1.8kHz
Amplification Acoustic Channel
> 0 to 100 dB
Magnetic Channel
> 0 to 100 dB
Display Range
00.0 ms to 99.9 msec
Overflow Display
”OVFL” for distance values > 100 ms
Frequency Range
120 Hz to 1.8 kHz (acoustic)
Display
Large, easy-to-read 3.5” color LCD with backlight
Power
8 standard alkaline or replaceable lithium AA cell batteries
Battery Life
Alkaline, 24hours continuous : Lithium, 30hours continuous :
>150hours intermittent (approx.)
Temperature Range
Operating: -4°F to 122°F (-20°C to 50°C)
Storage:
-4°F to 149°F (-20°C to 65°C)
Environmental
Rated to IP54
Humidity
95% noncondensing
Dimensions
8 L x 6.5 W x 3.25 H in. (203 L x 165 W x 83 H mm)
Weight
2.15 lb (.98 kg)
Behind-the-head headphones fit
comfortably even when worn
with safety helmet.
FEATURES AND BENEFITS
n
Lightweight receiver with durable weather-resistant
enclosure.
n
Comfortable neck strap allowing two-handed operation
and “hands-free” carrying of the unit.
n
Easy-to-read graphical display of acoustic and
electromagnetic signal levels.
n
Measures distance to cable fault by calculating
electromagnetic surge/acoustic emission, providing fast,
accurate fault pinpointing.
n
Bargraph magnetic field strength indicator.
n
Backlit LCD visible in direct sunlight.
n
Behind-the-head headphones.
n
A sturdy yet flexible wind guard insulates the ground
microphone from ambient noises.
n
Durable carrying case holds all components.
n
Optional noise-cancelling headphones are available.
SPECIFICATIONS
Operating Mode
Acoustic and electromagnetic pinpoint fault location — coincidence
or time delay — pinpoint fault location — relative distance to fault
— direction to fault indication
Range
0 to 99.9 ms
Resolution
0.1 ms
Outputs
Loudspeaker
1 x jack for headphones
Volume
Adjustable for both headphone and loudspeaker
Acoustic Gain
Manual
Electromagnetic Gain
Manual