Atec Megger-247000 Series User Manual
Page 4
UK
Archcliffe Road, Dover
CT17 9EN England
T (0) 1 304 502101
F (0) 1 304 207342
UNITED STATES
4271 Bronze Way
Dallas, TX 75237-1019 USA
T 1 800 723 2861
T 1 214 333 3201
F 1 214 331 7399
OTHER TECHNICAL SALES OFFICES
Norristown USA, Toronto CANADA,
Mumbai INDIA, Trappes FRANCE,
Sydney AUSTRALIA, Madrid SPAIN
and The Kingdom of BAHRAIN.
ISO STATEMENT
Registered to ISO 9001:2000 Reg no. Q 09250
Registered to ISO 14001 Reg no. EMS 61597
DLRO247000_DS_en_V11
www.megger.com
Megger is a registered trademark
247000 Series
Digital Low Resistance Ohmmeters
Item (Qty)
Cat. No.
DLRO
®
Digital Low Resistance Ohmmeters
Dual-Pak, battery-operated (10A)
247000
Single-Pak, battery-operated (10A)
247001
Single-Pak/Low-Range, battery-operated (10A)
247002
Low-Range/High-Current, line- and
battery-operated (100A)
247100 or 247101
Included Accessories
Line cord, where applicable
17032
Instruction manual
AVTM24-1J
Optional Accessories
Test leads
See chart
100 ampere current supply
for Cat. No. 247000-3 and 247001-3
247120
ORDERING INFORMATION
OPTIONAL ACCESSORIES
Input Voltage Protection
To protect the instrument when testing battery straps, this
option provides input protection against accidental
overvoltage up to 30 volts.
The option should not be specified when the instrument
will be used to test transformers and other inductive
components. This option is available on Cat. No. 247000,
247001 and 247002 only. To order, add –11 to instrument
Cat. No.
100-Ampere Adapter Plug
Cat. No. 247000 and 247001 can be ordered with an
adapter plug to allow use with the 100 ampere current
supply, Cat. No. 247120.
This capability is required by some standard methods of
testing large switchgear. ANSI C37.09, Test Procedure for
AC High Voltage Circuit Breakers, and IEC
Recommendation, Publication 56-4, High Voltage
Alternating Current Circuit Breakers Cat. No. 247101, are
two such standards. Cat. No. 247100 comes standard with
this option. This option is not available with Cat. No.
247002. To order, add –3 to instrument Cat. No.
Calibration Shunts
These four-terminal calibrating resistance standards feature
a conservative current rating to ensure against overheating.
Each shunt provides two current terminals with knurled
Allen-head cap screws and two potential terminals with
slotted screw heads. Accuracy is ±0.25%.
Item (Qty)
Cat. No.
100 A adapter plug
for Cat. No. 247000 and 247001 only
Add –3
Input voltage protection
for Cat. No. 247000, 247001 and 247002 only
Add –11
230 V (nominal), 50/60-Hz operation
Add –47
Canvas carrying case for Cat. No. 247000
35788
Instrument carrying case
for Cat. No. 247001, 247002
218748
Carrying case for leads
18313
Field test shunt, 10
Ω, current rating 0.001 A
249000*
Field test shunt, 1
Ω, current rating 0.01 A
249001*
Field test shunt, 0.1
Ω, current rating 1 A
249002*
Field test shunt, 0.01
Ω, current rating 10 A
249003
Field test shunt, 0.001
Ω, current rating 100 A
249004
Field test shunt, 0.0001
Ω, current rating 500 A
249005
Certificate of Calibration, NIST
CERT-NIST
*Furnished with protective shield