Ti400
Ti300
Ti200
Temperature
Temperature measurement range
(not calibrated below -10 °C)
-20 °C to +1200 °C
(-4 °F to +2192 °F)
-20 °C to +650 °C
(-4 °F to +1202 °F)
Temperature measurement
accuracy
± 2 °C or 2 % (at 25 °C nominal, whichever is greater)
On-screen emissivity correction
Yes (by number and table)
On-screen reflected background
temperature compensation
Yes
On-screen transmission correction
Yes
Imaging performance
Image capture frequency
9 Hz refresh rate or 60 Hz refresh rate depending upon model variation
Detector type
Focal Plane Array, uncooled
microbolometer, 320 x 240 pixels
Focal Plane Array, uncooled
microbolometer, 240 X 180 pixels
Focal Plane Array, uncooled
microbolometer, 200 X 150 pixels
Thermal sensitivity (NETD)
≤ 0.05 °C at 30 °C target temp (50 mK)
≤ 0.075 °C at 30 °C target temp (75 mK)
Total pixels
76,800
43,200
30,000
Infrared spectral band
7.5 μm to 14 μm (long wave)
Visual (visible light) camera
Industrial performance 5.0 megapixel
Standard infrared lens type
Field of view
24 ° x 17 °
Spatial resolution (IFOV)
1.31 mRad
1.75 mRad
2.09 mRad
Minimum focus distance
15 cm (approx. 6 in)
Optional telephoto infrared lens type, available soon
Field of view
12 ° x 9 °
Spatial resolution (IFOV)
0.65 mRad
0.87 mRad
1.05 mRad
Minimum focus distance
45 cm (approx. 18 in)
Optional wide-angle infrared lens type, available soon
Field of view
46 ° x 34 °
Spatial resolution (IFOV)
2.62 mRad
3.49 mRad
4.19 mRad
Minimum focus distance
15 cm (approx. 6 in)
Focus mechanism
LaserSharp
™
Auto Focus System
Yes
Advanced Manual Focus
Yes
Image presentation
Palettes
Standard
Ironbow, Blue-Red, High Contrast, Amber, Amber Inverted, Hot Metal, Grayscale, Grayscale Inverted
Ultra Contrast™
Ironbow Ultra, Blue-Red Ultra, High Contrast Ultra, Amber Ultra, Amber Inverted Ultra,
Hot Metal Ultra, Grayscale Ultra, Grayscale Inverted Ultra
Level and span
Smooth auto-scaling and manual scaling of level and span
Fast auto toggle between manual
and auto modes
Yes
Fast auto-rescale in manual mode
Yes
Minimum span (in manual mode)
2.0 °C (3.6 °F)
Minimum span (in auto mode)
3.0 °C (5.4 °F)
IR-Fusion
®
information
Picture-In-Picture (PIP)
Yes
Full screen infrared
Yes
AutoBlend™ mode
Yes
Color alarms (temperature alarms)
High-temperature , low-temperature, and isotherm (user-selectable)
Image capture and data storage
Image capture, review,
save mechanism
One-handed image capture, review, and save capability
Storage medium
Micro SD Memory Card, on-board flash memory, save-to-USB capability, direct download via USB-to-PC connection
File formats
Non-radiometric (.bmp) or (.jpeg) or fully-radiometric (.is2) Video*: non-radiometric (MPEG - encoded .AVI) and fully-radiometric (.IS3)
No analysis software required for non-radiometric (.bmp, .jpg and .avi*) files
Export file formats w/SmartView
®
software
BMP, DIB, GIF, JPE, JFIF, JPEG, JPG, PNG, TIF, and TIFF
Memory review
Thumbnail view navigation and review selection
Other time-saving and productivity features
Voice annotation
60 seconds maximum recording time per image; reviewable playback on imager
IR-PhotoNotes™
Yes
Wi-Fi connectivity
Yes, to PC, iPhone
®
, iPad
®
and WiFi to LAN*
Text annotation*
Yes
Video recording*
Standard and Radiometric
Streaming Video
Via USB to PC and HDMI to HDMI compatible screen
CNX™ Wireless System*
Yes*
Cardinal Compass*
Yes*
GPS coordinates and recording
Yes
Auto capture
(temperature and interval)
*
Yes*
Remote control and operation (for
special and advanced applications)
Yes
No
No
* Coming soon via firmware update. Users notified via SmartView software when available.