Accuracy

±10% of setting

Beam Level

Adjustable relative to preamble (Note 6, 8 and 10)

Range

-14.0 to +13.0 dB

Resolution

1.0 dB steps

Accuracy

±1.0 dB, -3.0 to +13.0 dB
±2.0 dB, -14.0 to -4.0 dB

SIDE LOBES

Relative to beam level

Level

-20.0 dB, ±1.0 dB

Main Path to Multi-path

±1.0 dB tracking error

FADE RATE
Frequency Range

Selectable 0.05, 1 and 1000 Hz

Accuracy

±1.0 %

Steps

Eight discrete steps that approximate a sine wave

Clearance Pulses (Note 9)
Position

Two pulses spaced equidistant from 0.0°

Angle Resolution

±0.05°

Angle Accuracy

±0.05°

Pulse Width

50.0

µ

s, ±5.0

µ

s

AMPLITUDE
Range

-3.0 to +13.0 dB

Resolution

1.0 dB steps

Accuracy

±1.0 dB

A

AD

DD

DIIT

TIIO

ON

NA

AL

L F

FU

UN

NC

CT

TIIO

ON

NS

S

AZ to EL RATIO

Selectable so Azimuth to Elevation function ratio is 0 or -75 dB

Accuracy

±2 dB

Interference Modulation
Propeller Modulation
Frequency

Variable 1 to 199 Hz

Resolution

1.0 Hz steps

Accuracy

±1%

Duty Cycle

-12 dB, ±2 dB applied for 15%, ±1%

Sync

Not in sync with any function

6.75 HZ MODULATION
Frequency

6.75 Hz

Accuracy

±1%

Level

Selectable ±6.0 dB square wave modulation to main beam (Note 6
and 10)

Accuracy

±1.0 dB

Sync

Not in sync with any function

MORSE CODE
Selection

Off, selectable or Continuous Tone

OSCILLOSCOPE SYNC
Selection

Selectable to occur at start of any function, basic or auxiliary data
word

Amplitude

Positive TTL pulse approximately 14

µ

s wide.

Note:

Sync control specifies to which function or data word the tests
in Table 1 apply.

FUNCTION

APPLICATION

P PARITY

CONTROLS PREAMBLE PARITY

6.75 Hz

ENABLES OR DISABLES 6.75 Hz MODULATION

UPDATE

CONTROLS % UPDATE RATE

FADE RATE

CONTROLS FADE RATE (APPLIED TO MULTI-PATH
BEAM)

SYMMETRY

CONTROLS BEAM SYMMETRY

PROP MOD

CONTROLS PROPELLER MODULATION
FREQUENCY

PFE

MEASUREMENT OF PATH FOLLOWING ERROR

CMN

MEASUREMENT OF CONTROL MOTION NOISE

Table 1 - Oscilloscope Sync

FUNCTION UPDATE RATE
Selection

100%, 75%, 55%, 45%, 25% and 0%

Accuracy

±3.9 %

FUNCTION

UPDATE RATE

AVERAGE RATE OVER 10

SECONDS

AZ

100 %

13.0 ±0.5 Hz

HiAZ

100 %

39.0 ±1.5 Hz

BAZ

100 %

6.5 ±0.25 Hz

EL

100 %

39.0 ±1.5 Hz

FUNCTION PREAMBLE PARITY
Selection

Function identified by Oscilloscope Sync selection is candidate to have
its parity bits individually inverted to provide a change in parity.

SCANNING BEAM TIME SYMMETRY
Selection

0 (OFF), ±60

µ

s in 1

µ

s steps referenced to proper timing from pre-