Fsm-60r12 fusion splicer – Atec Fujikura-FSM-60r12 User Manual
Page 2
877-529-9114
The Fiber Optic Marketplace LLC®
www.fiberoptic.com
AFL/FUJIKURA FUSION SPLICERS
SPLICING EQUIPMENT
AFL / FUJIKURA
FSM-60R12 Fusion Splicer
Accessories Recommended for the FSM-60R12
DESCRIPTION
PART #
Cleavers and Strippers
CT-30 Cleaver
S014076
HJS-02 Hot Jacket Stripper
S010340
Batteries and Power Cords
ADC-13 AC Adapter
S014535
BTR-08 Battery
S014540
DCC-14 Power Cord (connects ADC-13 to BTR-08)
S014541
DCC-12 Power Cord
(connects ADC-13 to cigarette lighter socket)
S013552
DCC-13 Power Cord
(connects ADC-13 to power source via alligator clips)
S013556
Fiber Holders (pairs)
FH-50-12
S013828
FH-50-10
S013824
FH-50-8
S013820
FH-50-6
S013816
FH-50-4
S013812
Specifications
PARAMETER
VALUE
Model
FSM-60R12 Fusion Splicer
Applicable Fibers
Single-mode (ITU-T G.652), Multimode (ITU-T G.651), DS (ITU -T G.653), NZDS (ITU-T G.655)
Fiber Count
Single, 2, 4, 5, 6, 8, 10, 12
Cladding Diameter
125µm
Coating Diameter
Ribbon: 0.25mm to 0.4mm, Single: 250µm and 900µm
Fiber Cleave Length
10mm
Typical Average Splice Loss
0.05dB with SM, 0.02dB with MM, 0.08dB with DS, 0.08dB with NZDS; measured by cut-back method relevant to ITU-T and IEC standards
Splicing Time
Typical 20 seconds with standard single-mode fiber
Arc Calibration Method
Automatic, real-time by using results of previous splice when in AUTO mode; manual arc calibration function available
Splicing Modes
100 preset and user programmable modes
Splice Loss Estimate
Based upon dual camera cladding alignment data
Storage of Splice Result
Last 2000 splice results stored in the internal memory
Fiber Display
X or Y, or both X and Y simultaneously; front or rear monitor display options with automatic image orientation
Magnification
35X to 90X
Viewing Method
Dual cameras with 4.1 inch TFT color LCD monitor with anti-reflective coating
Operating Condition
0 to 3,660m above sea level, 0 to 95% RH, and -10 to 50°C respectively.
Mechanical Proof Test
1.96 to 2.25N
Tube Heater
Built-in tube heater with 30 heating modes; auto-start function
Tube Heating Time
Typical 50 seconds with FP-5 sleeve, 40 seconds with FP3 (40), 35-55 seconds with Fujikura micro sleeves
Protection Sleeve Length
60mm, 40mm, Micro
Splice/Heat Cycles with Battery Typical 90 cycles with power save functions activated
Power Supply
Auto voltage selection from 100 to 240V AC or 10 to 15V DC with ADC-13, 13.2V DC with BTR-08 battery
Terminals
USB 1.1 (USB-B type) for PC communication, Mini-DIN (6-pin) for HJS-02/03 and SH-8 tube heater
Wind Protection
Maximum wind velocity of 15m/s. (34 mph)
Dimensions
136W x 161D x 143H (mm) / 5.3W x 6.3D x 5.6H (inches)
Weight
2.1 kg (4.6 lbs) with AC adapter ADC-13; 2.5kg (5.5 lbs) with BTR-08 battery
DESCRIPTION
PART #
Fiber Holders (pairs) – continued
FH-50-2
S013808
FH-50-250 (250µm coated single fiber)
S013800
FH-50-900 (900µm jacketed single fiber)
S013804
Miscellaneous
ELCT2-20A Electrodes
S013532
ASW-02 Splicing Workstation
S010532
JP-05 Splice Sleeve Cooling Tray
S014537
MGS-06 Magnifier (with bracket)
S014555
FAT-04 Fiber Arrangement Tool
S010212
FAA-03 Ribbon Forming Adhesive (4 oz. bottle)
S008720
FAA-03 Ribbon Forming Adhesive (0.5 liter bottle)
S008622
CC-24-60R Transit Case (fits FSM-60R12 only)
S014558
One Year Extended Warranty
S012996
Two Year Extended Warranty
S013000