Specifications, Standard package, Item p/n quantity – Atec Fitel-S178A User Manual
Page 3
SPECIFICATIONS
Applicable Fibers
SM, MM, DSF, NZD, EDF, BIF/UBIF (Bend insensitive fiber)
Cladding Diameter
80~150 μm
Coating Diameter
100~1,000 μm
Fiber Cleave Length
5~16 mm
Average Splice Loss
SM: 0.02 dB, MM: 0.01 dB, DSF: 0.04 dB, NZD: 0.04 dB
Splice Time
7 seconds (semi-auto mode)
9 seconds (regular mode)
Heat Time
25 seconds
*6
(S922: 40 mm Sleeve, S921: 60 mm Sleeve) (Pre-heat mode)
31 seconds
*6
(S922: 40 mm Sleeve, S921: 60 mm Sleeve) (regular mode)
Splice Programs
Max. 150
Automatic Splicing Selection
SM: SM, DSF, NZD, BIF/UBIF, MM: MM
Heat Programs
Max. 18
Automatic Heating Start
Available
Applicable Sleeves
20/40/60 mm
Fiber Holding
Tight holder (Loose tube applicable) or Removal Fiber Holder System
Tension Test
1.96 N
Return Loss of Splice
60 dB or greater
Attenuation Splice Function
Intentional high splice loss of 0.1 dB to 10 dB (0.1 dB step) can be made for an inline fixed attenuator
Fiber Image Magnification
304X, 608X
Splice Memory
Max. 2,000
Image Capture Capacity
Last 100 images to be automatically captured + Up to 24 images to be stored permanently
Dimension
127W × 199D × 105H mm (not including shock absorber)
159W × 231D × 130H mm (including shock absorber)
Weight
1.9 kg (without battery)
2.3 kg (with two batteries)
Monitor
3.5” color LCD monitor
Data Output
USB ver.2.0 mini
Battery Capacity
Typical 80 splice/heat cycles with single battery
*7
Typical 200 splice/heat cycles with 2 batteries
*8
Altitude
5,000 mh
Wind Protection
Max. wind velocity of 15 m/s.
Operating Temperature
-10 to +50°C (0 to 95% Relative Humidity [Non-Condensing])
Storage Temperature
-40 to +60°C (0 to 95% Relative Humidity [Non-Condensing])
Humidity
0 to +95% RH (non-condensing)
Power Source
AC Input 100 to 240 V (50/60 Hz), DC Input 11 to 17 V without any change of hardware
*6 The first heating after turning on the power can be longer than the usual heating time.
*7 The number of the splicing and heating the machine can produce using a fully charged brand new battery at room temperature of 20°C,
semi-auto mode for splicing and regular mode for Heating. Depending on the condition of the batteries and operation environment, the number can vary.
*8 The number of the splicing and heating the machine can produce using 2 fully charged brand new batteries at room temperature of 20°C,
semi-auto mode for splicing and regular mode for Heating. Depending on the condition of the batteries and operation environment, the number can vary.
STANDARD PACKAGE
Item
P/N
Quantity
S178A Main Body
S178-A-A-0001
1
Hard Carrying Case
HCC-01
1
Battery Pack
Depending on the package
S943B
1 or 2
Spare Electrodes
S969
1pair
AC Adaptor for S178A and
S958C
S976A
1
AC Cable Cord
—
1
Electrode Sharpener
D5111
1
Cleaning Brush
VGC-01
1
Tool case
TCC-01
1
User Manual
FTS-B405
1