beautypg.com

Atec Fluke-Networks-FTK1450 User Manual

Page 4

background image

General Specifications

Temperature range

Operating: -10

0

C to 50

0

C

Storage: -20

0

C to 50

0

C

Humidity range

95% (10

0

C to 35

0

C) non-condensing;

75% (35

0

C to 40

0

C) non-condensing;

uncontrolled <10

0

C

Certifications

CE, CSA, N10140, Class 1 laser-safe

Dimensions

Power meter: 6.4 in x 3.2 in x 1.5 in

(16.5 cm x 8.0 cm x 3.9 cm)

MM/SM sources: 5.6 in x 3.2 in x 1.6 in

(14.2 cm x 8.1 cm x 4.1 cm)

Weight

Power meter: 11.5 oz (325 g)

MM/SM sources: 9.8 oz (278 g)

Optical Sources

Optical output connector

Fixed SC

Emitter type

850/1300: LED

1310/1550: FP Laser

FindFiber: Laser

Emitter wavelengths

850, 1300, 1310, 1490, 1550, 1625

Power output (minimum)

MM: ≥ -20 dBm

SM: ≥ 8 dBm minimum;

-7 dBm nominal

Power output stability

(8 hours)

MM: +/- 0.1 dB over 8 hours

SM: +/- 0.25 dB over 8 hours

MM battery life

(2 x AA IEC LR6)

40 hours typical

SM battery life

(2 x AA IEC LR6)

30 hours typical

FindFiber battery life

(2 x AA IEC LR6)

80 hours typical

Optical Power Meter

Power measurement accuracy +/-0.25 dB
Optical connector

Removable adapter; SC adapter standard;

Optional adapters include LC, ST

Detector type

InGaAs

Calibrated wavelengths

850, 1300, 1310, 1490, 1550, 1625

Power measurement range

850: 10 to -52 dBm

1300, 1310, 1490, 1550, 1625: 10 to -60

dBm

Power measurement linearity

850 nm: +/- 0.2 dB; +/- 0.2 dB for power

from 0 dBm to -45 dBm, +/- 0.25 dB for

power < -45 dBm; 1300 nm, 1310 nm, 1490

nm, 1550 nm, 1625 nm: +/- 0.1 dB; +/- 0.1

dB for power from 0 dBm to -55 dBm, +/-

0.2 dB for power > 0 dBm and < -55 dBm

Resolution

0.01 dB

Battery life

>50 hours typical

Memory

1000 loss or power measurements

Serial communication

physical interface

USB

SimpliFiber Pro Kit Ordering Information
Model

Description

SFPOWERMETER

SimpliFiber Pro optical power meter

SFSINGLEMODESOURCE

SimpliFiber Pro singlemode 1310/1500 source

FTK1000

Basic Fiber Verification Kit: Includes SimpliFiber

Pro optical power meter, 850/1300 multimode

source, and carrying case

FTK1300

Multimode Fiber Verification Kit: Includes

SimpliFiber Pro optical power meter,

850/1300 multimode source, VisiFault VFL,

FT120 FiberViewer, FindFiber Remote ID sources,

and carrying case; ST and LC adapter

FTK1350

Multimode Fiber Verification Kit with FT500

FiberInspector Mini: Includes SimpliFiber Pro

optical power meter, 850/1300 multimode source,

VisiFault VFL, FT500 FiberInspector Mini,

FindFiber Remote ID sources, and carrying case;

ST and LC adapter

FTK1450

Complete Fiber Verification Kit with FT500

FiberInspector Mini: Includes SimpliFiber Pro

optical power meter, 850/1300 multimode source,

1310/1550 singlemode source, VisiFault VFL,

FT500 FiberInspector Mini, two (2) FindFiber

Remote ID sources, and carrying case; ST and LC

adapter, NFC-Kit-Box fiber optic cleaning kit

FTK2000

Singlemode Fiber Verification Kit: Includes

SimpliFiber Pro optical power meter,

1310/1550 singlemode source, and carrying case

FindFiber

One (1) FindFiber Remote ID source

FindFiber-6

Set of six (6) FindFiber Remote ID sources

GLD-FTK

Gold Support package for SimpliFiber Pro

SimpliFiber Pro Accessories Ordering Information
Model

Description

NFK1-SMPLX-SC

62.5 uM simplex reference cord set (SC/SC x 2);

special patented damage-resistant end-faces

NFK1-SMPLX-LC

62.5 uM simplex reference cord set (SC/LC, LC/LC);

special patented damage-resistant end-faces

NFK1-SMPLX-ST

62.5 uM simplex reference cord set (SC/ST, ST/ST);

special patented damage-resistant end-faces

NFK2-SMPLX-SC

50 uM simplex reference cord set (SC/SC x 2);

special patented damage-resistant end-faces

NFK2-SMPLX-LC

50 uM simplex reference cord set (SC/LC, LC/LC);

special patented damage-resistant end-faces

NFK2-SMPLX-ST

50 uM simplex reference cord set (SC/ST, ST/ST);

special patented damage-resistant end-faces

NFK3-SMPLX-SC

SM simplex reference cord set (SC/SC x 2);

special patented damage-resistant end-faces

NFK3-SMPLX-LC

SM simplex reference cord set (SC/LC, LC/LC);

special patented damage-resistant end-faces

NFK3-SMPLX-ST

SM simplex reference cord set (SC/ST, ST/ST);

special patented damage-resistant end-faces

NFA-SC-SINGLE

SC interchangeable adapter

NFA-LC-SINGLE

LC interchangeable adapter

NFA-ST-SINGLE

ST interchangeable adapter

Test Equipment Depot - 800.517.8431 - 99 Washington Street Melrose, MA 02176

FAX 781.665.0780 - TestEquipmentDepot.com