Atec JDSU-C8555 User Manual
Atec Equipment
Technical specifications
Display
High visibility touchscreen TFT color display, 10’4 inches,
LCD 800 x 600
Storage
Internal memory
8 Mb
Hard disk
Min 6 GB
Floppy disk drive (optional)
3.5 inches
CD read/write (optional)
Input/output interfaces
RS232C, 2 x USB,VGA, RJ-11
modem (optional), RJ-45 Ethernet,
DIN external switch, compact flash*
* Compact flash receptacle is used for the Transport Module
application card
Optional Interfaces
Power meter (optional)
+ 10 to -50 dBm (-45 dBm from
800 nm to 1250 nm)
Talk set (optional)
45 dB range
VFL (optional)
1 mW, Class 2 laser, universal
push/pull connector video
Video microscope (optional)
250x, 400x, through USB port
Power Supply, Battery
Battery type
Internal standard removable Li-Ion batteries
Operation time
Up to 1.5 hours at 10 Gb/s rates
with one battery (two batteries possible)
Internal charger
Power supply, AC/DC
Transport Module power adapter:
100-240 V, 50-60 Hz, 2A, Output: 24 V, 6.25 A
To be used when operating a MTS-8000
with the Transport Module.
Charging Time
One battery, unit non operating: 3 hours
One battery, unit in operation: up to 9 hours
Trickle charge
Yes
General specifications
Module physical specifications
Height
2.13 inches/5.41 cm
Width
12.16 inches/30.88 cm
Depth
9.96 inches/25.3 cm
Weight
5.5 lbs/2.5 kg
Combined physical specifications
for Transport Module when attached to the base unit a battery
module with one battery installed.
Height
5.8 inches/14.73 cm
Width
12.16 inches/30.89 cm
Depth
9.96 inches/25.3 cm
Weight
14.69 lbs/6.6 kg
Operating Temperature
Operational temperature
0º C to +40º C
Storage temperature
-20º C to +60º C
Humidity
5% to 95% without condensation
Shock/Drop Height
Shock - Per IEC 60068-2-27 & 29:The unit resists the
following test:
- Three shocks per axis along each of the three axes, with
power off
- Impacts of 15 G, 1/2 sine, duration 11 ms, at 10 second
intervals
Bumps - Per IEC 60068-2-27 & 29:The unit resists the
following test:
- 1,000 jolts per axis along each of the three axes, with
power off
- Jolts of 15 G, 1/2 sine, duration 6 ms, at 1 second intervals
Drop - Meets requirements as specified in IEC 721-3-7:
- Total of six (6) impacts dropped from a height of 50 cm
(20”). One (1) impact on each of its’ six sides onto a flat
plywood surface.
EMI/ESD
CE Mark Class A
Ethernet
10 GigE LAN/WAN* PHY
Connector Type
FC, SC, ST, LC, DIN
10 GigE LAN/WAN Phy Rates
10.3 Gbps, 10 Gbps
* For 10 Gbps WAN, SONET/SDH capability can be located in
the SONET/SDH section of this datasheet.
Flow Control
Supported
Modes of Operation
Terminate, Monitor, Loopback
Configurations
Single and Dual Port*
*Dual Port testing for 10 GigE requires two Transport Modules
Layer 2 (Ethernet) Traffic Generation
Constant, Bursty, Ramp, Flood Configurable Source and
Destination Address, Frame Format,Type Field (for DIX),
Frame Length (including Jumbo and Undersized),VLAN Tag,
Pause Frames, Payload, Utilization %
Layer 3 (IP) Traffic Generation
Configurable Source and Destination IP Address,DNS Server Type,
Tx Payload,TOS/DSCP,TTL,Packet Size Length (34 – 1500 bytes),
Ping,Traceroute
Layer 2 (Ethernet) Traffic Filtering
MAC Source and Destination Address, Frame Type/Length,
VLAN Tagged or Untagged Frames
Layer 3 (IP) Traffic Filtering
Source and Destination IP Address,TOS Type (TOS/DSCP)
Bit Error Rate Testing Patterns
Layer 1 (Unframed) Bit Error Testing
Patterns
Pattern Segments
Per 802.3ae-2002, Section 52.9.1
An
0x3C8B44DCAB6804F
Bn
0x34906BB85A38884
Patterns
Per 802.3ae-2002, Section 52.9.1
BnBiBnBi
AnAiAnAi
PRBS31(B)*
*(B) This is the test pattern checker defined in 49.2.12 of
802.3ae-2002
Layer 2 (Framed) Bit Error Testing Patterns
PRBS (2^23-1,2^31-1 and inverted selections)
All 1s
All 0s
User defined (32 bits)
Error Insertion
Code Errors
Single, Burst, Rate
Bit Errors
Single, Rate
FCS Errors
Single, Burst
IP Checksum
Single, Burst
ATP Payload
Single, Burst
Key Results
LED’s
Signal Status
Sync Acquired
Link Active
Frame Detected
VLAN Tagged Frame Detected
Pause Frame Detect
Acterna Frame Detect
IP Packet Detect
Signal
Optical Receive Level (dBm)
Remote Fault Seconds
Local Fault Seconds
L1 Errored Stats
Code Violation Rate, Code Violation Seconds,
Code Violations, Pattern Errors, Pattern Error Rate, Pattern
Error Free Seconds, Pattern Error Free Seconds %, Pattern
Errored Seconds, Bit Error Rate, Bit Errors
L2 Link Stats
Delay, Frame Rate, Frame Size, Service Disruption (micro
seconds),Total Utilization,Tx/Rx Mbps,Tx/Rx Mbps Data
L2 Link Counts
Frame Lengths (Binning), Pause Frames, Rx/Tx Frames,
Tx/Rx Acterna Frames,Tx/Rx Frame Bytes, Span Tree
Frames, Unicast Frames,VLAN Frames,VLAN ID,VLAN
Priority, Broadcast Frames, Multicast Frames
L2 Errored Stats
Code Violation Rate, Code Violation Seconds, Code
Violations, Errored Blocks (PCS), Errored Frames, FCS
Errored Frames, Frame Loss Ratio, Jabbers, Lost Frames,
Oos Frames, Runts, Undersized Frames
TRANSPORT MODULE