Atec JDSU-SmartClass-OTS-55 User Manual
Page 3
3
Specifications
SMARTCLASS OTS-55 Optical Talk Set
General data
Operating wavelength
1550 nm
Dynamic range
≥ 45 dB (single mode)
Can also be used with
multimode fibers (50/125/62.5/125 µm); ≥ 10 km
Optimum fiber type
Single mode 9/125 µm
Operation modes
headset or speaker phone
Compatibility
MTS/T-BERD-6000/8000; OFI-2000
Visual fault locator option
Wavelength
approx. 635 nm
Power output
approx. -5 dBm (SMF-28 fiber,
class II laser product)
Optical connector
Universal push/pull adapter (UPP)
for standard 2.5 mm connector system
[use S3122 adapter for LC connectors (see next page)]
Display
Graphical display
Resolution of 128 × 64 dots
Backlight function switchable via separated key
Optical connector
Optical connector interchangeable adapter from
2150/00.xx range
2.5 mm plugs
FC, ST, SC, DIN
1.25 mm plugs
LC
Power supply
Four dry batteries Mignon/AA, 1.5 V or NiMH rechargeable cells
Mignon/AA 1.2 V
Operating time from dry batteries (in headset mode) >60 h
Batteries/NiCd/NiMH power saving mode
AC line operation via separate AC adapter/charger SNT-121A
Integrated fast battery charging function
2 hours
Electromagnetic compatibility
Corresponds to IEC 61326 (CE conformance)
Ambient temperature
Nominal range of use
-10 ºC to +55 ºC
Storage and transport
-40 ºC to +70 ºC
Dimensions and weight
W × H × D approximately
95 Ч 60 Ч 195 mm
(3.74 Ч 2.36 Ч 7.68 in)
Weight approximately
500 g (1.1 lb)
Accessories for visual fault locator option
BN 2252/02
Adapter for 1.25 mm UPP
S3122
Adapter from 2.5 mm UPP to LC (1.25 mm)