SPECIFICATIONS

a

Probe EA … ED5091

Electric (E-)Field

Frequency range

(b)

300 kHz to 50 GHz

(EA5091, EC5091, ED5091)

3 MHz to 50 GHz

(EB5091)

Type of frequency response

Shaped, see table on page 2

Measurement range

0.5 to 600 % of Standard (Power Density)

Dynamic range

30 dB

CW damage level

2000 % of Standard

700 mW/cm²

Peak damage level

(c)

32 dB above Standard

Sensor type

Combined diodes/ thermocouples

Directivity

Isotropic (Tri-axial)

Readout mode / spatial assessment

Combined 3-axis (RSS)

UNCERTAINTY
Flatness of frequency response

(d)

Calibration uncertainty not included

±2 dB from Standard

Calibration uncertainty

(e)

±1.5 dB (< 1.8 GHz)
±0.7 dB (1.8 GHz to 40 GHz)
±1 dB (@ 45.5 GHz)

Linearity

Referred to 100 %

±3 dB (< 4 % of Standard)
±1 dB (4% to 12 % of Standard)
±0.5 dB (12 % to 600 % of Standard)

Isotropic response

(f)

typ. ±1 dB (≥ 10 MHz)

GENERAL SPECIFICATIONS
Calibration frequencies

0.3/ 3/ 10/ 30/ 100/ 300/ 750 MHz 1/ 1.8/ 2.45/ 4/ 8.2/ 10/ 18/ 26.5/ 40/ 45.5 GHz

Recommended calibration interval

12 months

Temperature range
Operating
Non-operating (transport)


0 °C to +50 °C
-40 °C to +70 °C

Humidity

5 to 95 % RH @ ≤25 °C

≤23 g/m³ absolute humidity

Size

350 mm x 104 mm Ø

Weight

240 g

Compatibility NBM-500

series

meters


(a)

Unless otherwise noted specifications apply at reference condition: device in far-field of source, ambient temperature 23±3 °C, relative air humidity 40% to 60%, sinusoidal signal

(b)

Cutoff frequency at approx. -3 dB

(c)

Pulse length 1µsec, duty cycle 1:1000

(d)

Frequency response can be compensated for by the use of correction factors stored in the probe memory

(e)

Accuracy of the fields generated to calibrate the probes

(f)

Uncertainty due to varying polarization (verified by type approval test for meter with probe). Ellipse ratio included and calibrated for each probe

ORDERING INFORMATION

Part number P/N

Probe EA5091, Shaped E-field, FCC for NBM, 300 kHz - 50 GHz, isotropic

2402/07

Probe EB5091, Shaped E-field, IEEE for NBM, 3 MHz - 50 GHz, isotropic

2402/08

Probe EC5091, Shaped E-field, SC6 Canada for NBM, 300 kHz - 50 GHz, isotropic

2402/09

Probe ED5091, Shaped E-field, ICNIRP for NBM, 300 kHz - 50 GHz, isotropic

2402/10