beautypg.com

Technical specifications, Ordering information – Atec Kaelus-RTF Series User Manual

Page 3

background image

RTF analysis modes

Numeric: Distance to maximum PIM + PIM Magnitude
Graphical: PIM vs. Distance, Return Loss vs. Distance, PIM + RL vs. Distance

Return Loss

Max Return Loss (from FFT analysis) is displayed on the iQA main PIM test screen
when the RTF module is attached

Residual PIM

< -115dBm/-158dBc max (<-125dBm/-168dBc typ) @2x +43dBm test tones

User interface ports

1x USB, 1x Auxiliary port (Type N female)
1x RF output (7-16 DIN female), 1x RF input (7-16 DIN male)

Power

+12V DC supplied via iQA auxiliary port

RF power (PIM)

2x +43dBm supplied by iQA

RF power (Return Loss)

-33dBm supplied by RTF module

Dimensions

5.0 x 3.5 x 2.9in (127 x 90 x 73mm)

Weight

2.2lbs (1.0kg)

Operating temperature range

-10°C to +40°C

Storage temperature range

-20°C to +60°C

Ingress protection (IP)

IP50 (operating)

Relative humidity

5% to 95% RH non-condensing

MODEL

DESCRIPTION

IQA MODELS SUPPORTED

RTF-1000A

RTF Module , 698-960 MHz

700L, 700H, 850, 900, 901

RTF-2000A

RTF Module , 1710 – 2170 MHz

1800, 1900, 1921, 2101

• USB cable, Auxiliary port cable and carrying case included with RTF Module.
• A and B-series iQA PIM analyzers require a factory upgrade to be compatible with the RTF module.

Contact Kaelus customer service to request an RMA number before returning equipment for upgrade.

Upgrade part numbers are model and band specific. See list below for upgrade part number.

PART NUMBER

DESCRIPTION

RTF-U700LA

RTF upgrade for iQA-700LA analyzer

RTF-U700LB

RTF upgrade for iQA-700LB analyzer

RTF-U700HB

RTF upgrade for iQA-700HB analyzer

RTF-U850A

RTF upgrade for iQA-850A analyzer

RTF-U850B

RTF upgrade for iQA-850B analyzer

RTF-U900A

RTF upgrade for iQA-900A analyzer

RTF-U900B

RTF upgrade for iQA-900B analyzer

iQA UPGRADE

PART NUMBER

DESCRIPTION

RTF-U901B

RTF upgrade for iQA-901B analyzer

RTF-U1800A

RTF upgrade for iQA-1800A analyzer

RTF-U1800B

RTF upgrade for iQA-1800B analyzer

RTF-U1921A*

RTF upgrade for iQA-1900A & iQA-1921A analyzers

RTF-U1921B*

RTF upgrade for iQA-1921B analyzers

RTF-U2101B

RTF upgrade for iQA-2101B analyzers

www.kaelus.com

*The iQA1921 operates over the PCS and AWS bands; however the RTF function is limited to the PCS band only.

WARNING: Use of the portable PIM analyzer in a radiating mode, for example when connected to an antenna not enclosed in an anechoic environment, may be
a violation of licensing regulations. Users should have permission in advance, from any licensed operators that might be affected by these tests. Furthermore,
radiating high RF power can pose a personnel risk. Specifications subject to change without notice.

TECHNICAL SPECIFICATIONS |

© 2012 Kaelus Inc. All Rights Reserved. RevA_1.12

RTF MODULE

ORDERING INFORMATION |

|3|