Kaelus-ipa-a_series_datasheet.pdf, Technical specifications continued, Models – Atec Kaelus-IPA-A Series User Manual
Page 2
Battery power
25.9 VDC, 2500 mAH Li-ion battery packs (removable)
Battery operating time
Depends on usage, 2 hr min. per battery pack
Battery charger
Output: 29.4 VDC, 1.2 Amp
DESCRIPTION
TX1 RANGE
TX2 RANGE
RX RANGE (PIM)
RTF MODULE *
iPA-0707A
700MHz LOW/HIGH
728-731.5MHz
741-764MHz
698-716MHz; 776-802MHz
RTF-1000A
iPA-0850A
850MHz
869MHz
879-894MHz
824-849MHz
RTF-1000A
iPA-0900A
GSM900
932.5-937.5MHz
949-960MHz
903-915MHz
RTF-1000A
iPA-0901A
EGSM900
925-935MHz
945-960MHz
880-915MHz
RTF-1000A
iPA-1800A
DCS1800
1805-1817.5MHz
1855-1880MHz
1730-1755MHz
RTF-2000A
iPA-1900A
PCS1900
1930-1937MHz
1965-1990MHz
1855-1880MHz
RTF-2000A
iPA-1921A
Dual Band PCS/
1930-1950MHz
1970-1990MHz
1850-1910MHz
RTF-2000A
AWS
1930-1950MHz
2110-2155MHz
1710-1755MHz
© 2013 Kaelus. All Rights Reserved.
iPA_A_RevG_11.13
www.kaelus.com
|2|
TECHNICAL SPECIFICATIONS CONTINUED |
ELECTRICAL
Dimensions
14.5 x 9.4 x 6.3in (369 x 240 x 160mm)
Weight
< 26lbs (12kg)
MECHANICAL
Operating temperature range
-10°C to +45°C (+14°F to +113°F)
Storage temperature range
-10°C to +60°C (+14°F to +140°F)
Ingress protection (IP)
IP54. IP67 when enclosed in optional hard case
Relative humidity
5% to 95% RH non-condensing
Mechanical shock
40G shock rating
ENVIRONMENTAL
MODELS |
iPA rugged hoist position
iPA shown with iAK-0060A ruggedized trans-
port case with full PIM testing accessories.
*Range to Fault is an optional accessory available for iPA test instruments
which enables users to measure distance to return loss faults as well as
distance to PIM faults. The RTF module is sold separately.
Dual Battery charger for standalone charging sold separately.
WARNING: Use of the portable PIM analyzer in a radiating mode, for example
when connected to an antenna not enclosed in an anechoic environment,
may be a violation of licensing regulations. Users should obtain permission
in advance from any licensed operators that might be affected by these tests.
Furthermore, radiating high RF power can pose a personnel risk.
Specifications subject to change without notice.
Receive band (100kHz steps)
See model table
Measurement noise floor
< -128dBm
Measurement range
-50dBm to -128dBm
RECEIVER