DryCal

®

DC-1 / DC-2

Primary Flow Calibrators

FEATURES:

Simple Operation—

Provides the user with accurate volumetric flow
readings with the push of a button.

Fast—

Saves valuable time.

Hands-free Auto-Mode—

Flow readings can be taken continuously in the
auto mode, providing hands-free calibration.

Three Interchangeable Flow Cells—

Three flow cells cover a broad range:
1 ml/min. to 50 Lpm.

Nist Traceable Certification—

Dimensional and timing accuracy traceable to
NIST standards.

Patented Graphite Composite Piston Assembly—

Eliminates the inherent inaccuracies and mess
associated with bubble soap.

Sealed Lead Acid Battery—

Can be charged indefinitely. The DC-1 and DC-2
DryCal can be used while charging.

Alphanumeric Display (LCD)—

Indicates the volumetric flow rate and the average
flow rate, battery charge level, and the number of
samples so far in a running average. The DC-2
also indicates the atmospheric pressure, the flow
rate corrected for standardized temperature, and
the average corrected flow rate.

Built-in Parallel Port—

Interfaces with most IBM

®

compatible printers.

RS-232 PC Data Logging Interface (DC-2M only)—

Downloads data directly to a PC.

Automatic Sampling—

DC-1: 10-reading averages with display of
running average
DC-2: 1 to 100-readings as running average (user
selected, 10 is default), repetition rate can be set as
instantaneous or 1 to 255 minutes (user selected)

Built-In Leak Test—

Quality assurance self-test allows user to
periodically verify flow cell integrity.

Tested by National Standards Labs—

· NIST

· The Japanese National Laboratory of Metrology

· The Netherlands Metrological Institute.

CE Approved

SPECIFICATIONS:

Size:

(DC-1)

5” x 5” x 2.75” / 127 mm x 127 mm x 70 mm

Weight:

(DC-1) 35 oz. / 1310 g

Size:

(DC-2)

7.75" x 4" x 7.75" / 197 mm x 102 mm x 219 mm

Weight:

(DC-2) 51 oz. / 140 g

Flow Ranges/ Air Flow Accuracy:
Model

Optimum Flow Range (1%)

Extended Flow Range*

DC-LC

15 ml/min.-300 ml/mi

1 ml/min - 500 ml/min

DC-MC

100 ml/min.-7 L/min.

10 ml/min - 10 L/min

DC-HC

500 ml/min. - 30 L/min.

50 ml/min - 50 L/min

Specifications based on averaged readings: lower limit is based on self-tested max. leakage.
*Contact BIOS for application assistance.
Note: All flow cells are interchangeable between DC-1 and DC-2 units.

Standardized (corrected) Accuracy (DC-2 only):
This represents the accuracy of the DryCal

®

DC-2 in the DC-2's optimum (±1%

volumetric) flow range when reading standardized flow (SLPM). These values were
calculated from the above temperature and pressure inaccuracies and the best-case error
of the DC-2 using the root-sum-square method.

Typical

Maximum

293 - 303 °K (20 - 30 °C)

± 1.1%

± 1.4 %

273 - 323 °K (0 - 50 °C)

± 1.3%

± 2.1 %

Battery System: 6V rechargeable, sealed lead acid, 6-8 hours typical operation.

AC Battery Charger/ Power Adapter: Wall-mounted, single station charger. Input: 100
to 120 VAC, 60Hz., Output: 12 VDC. (Optional: Input: 200 to 240 VAC, 50 Hz., Output:
12 VDC.)

Operating Modes: Single cycle, 10-readings, or auto-mode.

Temperature Operating Range: 0-55º C

Printer Port: Standard parallel (IBM Centronics, compatible with most printers.)

Serial Port: (DC-2 models only) Standard NZR data format, 9600-baud rate, 8 bit data,
1 start, 1 stop, no parity

Note: Not compatible with printers that require Microsoft

®

Windows

TM

.

Warranty: 2 year

Note: The recertification program offered by BIOS is elective and is not included as a
warranty item.

All specifications are subject to change. Please contact BIOS or visit our web

site at: www.biosint.com, for the most current information.

DryCal

®

DC-1/DC-2

GROUP ELECTRONICS PTY LIMITED
47-49 Southern Road (PO Box 55) MENTONE Victoria 3194
(PH) +61 (0)3 9484 1085 (FAX) +61 (0)3 9584 1867
(email) [email protected] (WEB) www.wtcorp.com.au