beautypg.com

Atec Acterna-DSAM-2500 Series User Manual

Page 5

background image

Specifications (preliminary)

Frequency

Range

4 to 1,000 MHz

Accuracy

±10 ppm at 77°F (25°C)

Tuning resolution

Analog 10 KHz

Digital 50 KHz

Channel bandwidth

DSAM-2500A 8 MHz

DSAM-2500B 6 MHz

Level measurement, analog

Signal types

CW, video and audio

(NTSC, PAL, and SECAM)

Range

40 to +60 dBmV

(1)

Resolution

0.1 dB

Resolution bandwidth

330 KHz

Accuracy

(2)

±1.5 dB typical @ 25°C

Level measurement, digital

Modulation types

QPR, QPSK, QAM (DVB/ACTS)

Range

40 to +60 dBmV

(1)

Resolution

0.1 dB

Resolution bandwidth

330 kHz

Accuracy

(2)

±2.0 dB typical @ 25°C

Upstream spectrum (ingress scan)

Spans

DSAM-2500A 4 to 65 MHz

DSAM-2500B 4 to 45 MHz

Sweep rate

1.8 seconds or faster

Display scaling and range

5 and 10 dB/division; 6 vertical divisions

Resolution bandwidth

330 kHz

Sensitivity

35 to 60 dBmV

(1)

DOCSIS/EuroDOCSIS compatibility

Version

DOCSIS 1.0 and 1.1

Upstream transmit range and diplexer crossover
(DOCSIS modes only)

DSAM-2500A 5 to 65 MHz 65/96MHz

(min. downstream DOCSIS

center freq. 100 MHz)

DSAM-2500B 5 to 42 MHz 42/88 MHz

(min. downstream DOCSIS

center freq. 91 MHz)

Upstream modulation

QPSK and 16 QAM as

instructed by CMTS

Transmitter output

At 25ºC, maximum 55 dBmV

with 16 QAM and 58 dBmV

with QPSK, (typical)

Downstream QAM demodulation

Modulation type

64 and 256 QAM, ITU-T J.83

Annex A, B or C (selectable)

Input range (lock range)

15 to +50 dBmV total

integrated power

(3)

from 55 to 1000 MHz

BER

(4)

Pre- and Post-FEC 10

-4

to 10

-9

MER

(4)

Range 64 QAM: 21 to 35 dB

Accuracy ±2 dB (typical)

Range 256 QAM: 28 to 35 dB

Accuracy ±2 dB (typical)

EVM

(4)

Range 64 QAM: 1.2% to 5.8%

Accuracy ±0.5% (1.2% to 2.0%)

±1.0% (2.1% to 4.0%)
±1.4% (4.1% to 5.8%)

Range 256 QAM: 1.1% to 2.4%

Accuracy ±0.6%

Symbol rate

Annex A, 5.057 to

6.952 Msps for 64 and 256 QAM

Annex B, 5.057 Msps for

64 QAM and 5.361 Msps for 256 QAM

Annex C, 5.274 Msps for

64 QAM and 5.361 Msps for 256 QAM

Interfaces

RF

75 ohm, F81 or BNC option

Max. sustained voltage 100 VAC, 140 VDC

RS232

Standard via DB9 on charger

module or optional direct cable

Printer compatibility

Epson and Citizen

Ethernet

RJ45, 10 base T,

TCP/IP and UDP supported

USB

v1.1 host mode, 150 mA

maximum slave (future firmware release)

Standards compliance

Shock and vibration

IEC 60068

Drop

IEC 61010

Handle stress

IEC 61010

Water resistance

MIL-STD-810E

Safety – emissions

EN 55022

Safety – immunity

EN 61000

General

Display

320 x 240, grayscale

selectable back light

Language support
(user interface and help system)

English in all models

No-charge second language

option of Spanish, French or German

Dimensions

4.75 x 9.75 x 2.75 in

(12 x 25 x 7 cm)

Weight

2 lb 12 oz (1.3 kg)

Storage and operating temperature range

0 to 120°F; 20 to +50°C

Power

NiMH removable pack, standard

Li-Ion removable pack, optional

Battery life

NiMH, 3 hours (typical)

Li-Ion, 4.5 hours (typical)

Charge time

NiMH, 5 hours (typical)

Li-Ion, 6.5 hours (typical)

Power supply input

90-264 VAC, 47-63 Hz

(1)

Typical, detectable range

(2)

Accuracy for levels between –20 to 60 dBmV
Additional uncertainty ±0.5 dB across –20°C to 50°C
Additional uncertainty ±1.0 dB from 4 MHz to 15 MHz

(3)

At 64 QAM

(4)

Accuracy and behavior from 100 MHz to 1000 MHz for
levels between –5 to 50 dBmV (typical)

figure 10 The DSAM meter and accessories shown

here within the optional transit soft case

5

Acterna is the world’s largest provider

of test and management solutions for

optical transport, access and cable

networks, and the second largest

communications test company overall.

Focused entirely on providing equip-

ment, software, systems and services,

Acterna helps customers develop,

install, manufacture and maintain

optical transport, access, cable,

data/IP and wireless networks.