beautypg.com

Atec Agilent-3326A User Manual

Page 2

background image

Resolution: 0.1% of full range for peak-peak entry

0.3% of full range for rms entry

0.01 dB for dBm or dBV entry

Accuracy: Relative to programmed value after self-calibration

0.001 Hz

100 kHz

1 MHz

13 MHz

+23.98 dBm

±0.1 dB

±0.3 dB

±0.6 dB

+3.98 dBm

±0.8 dB

-36.02 dBm

±0.2 dB

±0.5 dB

+1.0 dB

-56.02 dBm

Squarewave and Pulse Characteristics

Rise/fall time: :515 ns, 10% to 90% at full output

Overshoot: < 5% of peak-to-peak amplitude at full output

Pulse width range: 1 % to 99% of period or 20 ns, whichever is

greater

Pulse width resolution: 0.01% of period

Pulse width accuracy: <±l% of period ±20 ns

Amplitude accuracy: ±2%, 0.001 Hz to 100 kHz

DC Offset

Range: (See also option 002, high voltage output)

DC only: 0 to ±5 V

DC+AC: DC+AC peak <5V; Max. DC offset is affected by AC

range, Maximum is 4.5 V decreasing to 4.5 mV on lowest range

Resolution: 3 digits

Accuracy: (After self-calibration)

DC only. ±75 mV

DC+AC: (Sinewave) 10 Hz to 1 MHz: *2% of range

I MHz to 13 MHz: ±5% of range

Phase Offset

(Channel A vs B in Two-Phase mode)

Range: ±720 degrees

Resolution: 0.01 degree

Accuracy: After self-calibration, for equal-level sinewaves 1 V to

10 V peak-peak

0.1 Hz to 10 Hz

±0.5 degrees

10 Hz to 100 kHz

±0.2 degrees

100 kHz to 1 MHz

±0.3 degrees

1 MHz to 13 MHz

±2.0 degrees

Amplitude Modulation

Specifications apply to Channel A and Channel B with external

modulation or to Channel A internal modulation with Channel B as

the modulation source. External modulation is allowed in all modes;

internal modulation is allowed only in the two-channel mode.

Waveforms: Sine, square, or (external only) pulse, DC, etc.

Frequency Range: Carrier: DC to 13 MHz

Modulation: DC to 100 kHz

Modulation Depth: 0 to 100%

Phase Modulation

Specifications apply to Channel A and Channel B with external

modulation or to Channel A internal modulation with Channel B as

the modulation source. External modulation is allowed in all modes;

internal modulation is allowed only in the two-channel mode.

Waveforms: Sine, square, or (external only) pulse

Frequency Range: Carrier: DC to 13 MHz

Modulation: DC to 5 kHz

Phase Deviation: 0° to 360°

Frequency Sweep

Sweep Types: Linear, discrete

Sweep Forms: Triangle, ramp

Sweep Time: 5 ms to 1000 s

Sweep Elements (Discrete): 2 to 63 frequency pairs and dwell times,

user defined; dwell times = 5 ms to 1000 s/element

Maximum Sweep Width: 13 MHz

Output Combiner

Channel A and B are combined on the Channel A output. B output

is off. Combiner may be used in the two-channel, two-phase, and two-

tone modes. DC offset is automatically set to 0 V.

Frequency Range: DC to 13 MHz

Return Loss: >20 dB
Auxiliary Outputs (All Connectors are Rear-Panel BNC)

10 MHz reference-. +3 dBm output to phase lock other instruments

to the HP 3326A

10 MHz oven output: +3 dBm oven-stabilized frequency reference

(option 001 only)

X-axis drive: Linear ramp proportional to sweep time

Z-axis blank: TTL low during sweep

Sweep Marker TTL low at selected marker frequency in sweep

20-33 MHz LO: >I 00 mV square wave output offset 20 MHz from

Channel B output

Auxiliary Inputs (All Connectors are Rear-Panel BNC)

Reference Input: For phase-locking to an external frequency refer-

ence. Signal of 1,2,5, or 10 MHz, ±10 ppm, 0 to +20 dBm

External Trigger Input: TTL level to initiate linear or discrete sweep

on high to low transition

Channel A and B external phase calibration inputs

Channel A and B external amplitude modulation inputs

Channel A and B external phase modulation inputs

HP-IB Remote Control

Compatible with IEEE Standard 488-1978

Interface Functions:

SH I ,AH I ,T6,L4,SRI,RLI,PPO,DC 1,DTI,CO,EI
Option 001 High Stability Frequency Reference

Stability: ±5X10

-

°/week after 72 hours continuous operation

±1X10

-

7 /month

after 15 days continuous operation

Option 002 High Voltage Output

Multiplies the output level by 4 and expands the allowable DC off-

set range. Specifications apply to both channels in all modes with the

internal combiner off.

Frequency range: DC to 1 MHz

Output Impedance: <2 0, DC to 50 kHz; < 10 0, 50 kHz to 1 MHz

Amplitude range: 4 mV to 40 Vpp into > 1 k 0, <200 pF load without

DC offset (must be entered in peak-to-peak units only)

DC offset: ±20 V, independent of amplitude range. DC + AC peak

must not exceed 20 V
Option 003 Rear Terminal Outputs

Provides Channel A and B main outputs only on rear panel BNC's.

Front panel main outputs are removed. Specifications unchanged.
General

Power. 100/ 120/220/240 V, +5%, -10%,48 to 66 Hz; 120 VA, 150

VA with all options, 10 VA standby

Weight: 27 kg (60 lb) net, 37 kg (81 lb) shipping

Dimensions: 177 mm H x 425.5 mm W x 497.8 mm D (7 x 16

3

/ x

19

5/8")

Accessories Available

HP 15507A Isolator. For isolation of signal ground between frequen-

cy reference and instrument input/output

HP 9211-2656 transit case for protection in transportation and stor-

age

Ordering Information

Price

HP 3326A Two-Channel Synthesizer

$9,760

Option 001 High Stability Frequency Reference

$665

Option 002 High Voltage Output

$305

Option 003 Rear Terminal Outputs (Rear only)

N/C

Option 907 Front Handle Kit

S61

Option 908 Rack Flange Kit

$36

Option 909 Rack Flange and Handle Combination Kit

$92

Option 910 Extra Operating Manual

$102

Option 914 Delete Service Manual

less $115

Option W30 Ext. Warranty

$190