SPECIFICATIONS

Model 250L

POWER OUTPUT
Pulse Mode
Minimum ........................................................................... 750 watts
Duty Cycle .......................................................................... 10% maximum
Pulse Width ........................................................................ 8 milliseconds maximum
CW Mode
Nominal ............................................................................... 370 watts
Minimum.............................................................................. 250 watts
Linear @ 1dB compression................................................ 150 watts minimum

FLATNESS.....................................................................................

± 1.5 dB

FREQUENCY RESPONSE........................................................... 10 kHz - 220 MHz instantaneously

INPUT FOR RATED OUTPUT.................................................... 1.0 milliwatt maximum

GAIN (at maximum setting).......................................................... 54dB minimum CW, 59dB minimum Pulse

GAIN ADJUSTMENT (continuous range) .................................. 18 dB minimum

INPUT IMPEDANCE.................................................................... 50 ohms, VSWR 1.5:1 maximum

OUTPUT IMPEDANCE................................................................ 50 ohms, VSWR 2.0:1 maximum

MISMATCH TOLERANCE *........................................................ 100% of rated power without foldback. Will operate

without damage or oscillation with any magnitude
and phase of source and load impedance.

MODULATION CAPABILITY...................................................... Will faithfully reproduce AM, FM, or Pulse

modulation appearing on the input signal.

NOISE FIGURE ............................................................................ Noise floor data on request

HARMONIC DISTORTION (at 150 watts) ................................. Minus 20 dBc average
Below 115 MHz................................................................... Minus 15 dBc maximum
Above 115 MHz................................................................... Minus 25 dBc maximum

THIRD ORDER INTERCEPT POINT.......................................... 61 dBm typical

GATING CHARACTERISTICS
Pulse Mode Gating / CW Mode Blanking
Signal (into 180 ohms) .................................................. Plus or minus 2.5 to 6.0 VDC
Rise time ......................................................................... 20 microseconds maximum
Fall time ......................................................................... 5 microseconds maximum
RF Rise / Fall Time ............................................................. 10 nanoseconds maximum

PRIMARY POWER........................................................................ 100/110/120/200/208/220/240

± 5% VAC

(select via internal taps)

50/60 Hz, single phase
3700 watts maximum

CONNECTORS
RF Input............................................................................... Type BNC female
RF Output ............................................................................ Type N female
Gating/Blanking.................................................................. Type BNC female
Remote Control................................................................... 25 pin female subminiature D

COOLING ...................................................................................... Forced air (self contained fans)

WEIGHT......................................................................................... 84 kg (185 lb)

SIZE (WxHxD)............................................................................... 50.3 x 42.7 x 55.1 cm

19.8 x 16.8 x 21.7 in

* See Application Note #27