Measurement Characteristics
Measurement Techniques
Stat Mode (4500A only): Continuous sampling 0.5 M Samples per
second
Power Mode:
Random repetitive sampling system that
provides pre- and post-trigger data
Maximum Sample Rate
1MHz
Memory Depth
4 K/Channel
Vertical Resolution
0.025%, 12-bit A/D converter
Waveform Averaging
1 to 10,000 samples per data point
Waveform Storage
Two reference waveforms in internal non-
volatile memory
Trigger Channel Bandwidth: > 30 MHz typical
Sensor Characteristics
Power Detection Technique: Dual diode with selectable detector bandwidth
Log Amplifier:
The logarithmic amplifier in the sensor enables
the instrument to measure and analyze
changes in power exceeding 60 dB in a single
display range.
Internal Data
Sensor calibration factors, frequency range,
power range, sensor type, serial number and
other sensor dependent information are stored
in EEPROM within the peak power sensor.
Sensor Cable
The sensor cable is detachable from both the
sensor and instrument. The standard cable
length is 5 feet. Other cable lengths are 10 feet,
20 feet, 25 feet and 50 feet.
Rear Panel Connections
External Calibrator
Pulse Input
Provides a means of applying an external TTL
level signal to control the pulse rate and duty
cycle of the calibrator output (50 ohm input
impedance)
IEEE-488 Interface
Complies with IEEE-488-1978. Implements
AH1, SH1, T6, LE0, SR1, RL1, PP0, DC1, C0,
and E1
RS-232 Interface 1
Serial Printer/Plotter interface
RS-232 Interface 2
Diagnostic interface
Parallel Port
Parallel Pinter/Plotter interface
Optional Connectors
5
Rear Panel
Channel 1 and 2, Trigger 1 and 2, calibrator
output
Physical and Environmental
General
Manufactured to the intent of MIL-T-28800E,
Type III, Class 5, Style E
Disk Drive
3.5-inch, 1.44-MB (DOS compatible)
Display
VGA-compatible, seven-inch diagonal color
CRT with 640 x 480-pixel resolution. Waveform
display area resolution is 501 x 281.
Operating Temperature
0 to 50
O
C
Storage Temperature
-40 to 75
O
C
Humidity
95% + 5% maximum (non-condensing)
Altitude
Operating: 10,000 feet (3,000 meters)
Power Requirements
90 to 260 VAC, 47 to 440 Hz, 200 VA maximum
Dimensions
17.25 inches (43.8 cm) wide, 7 inches (17.8 cm)
high, 22 inches (55.9 cm) deep
Weight
38 pounds (17.2 kg) with second channel
installed
Hard Copy Output
The screen can be output to a printer or plotter
on the RS-232m parallel, IEEE-488 devices, or
to a file on disk.
HPGL Plotters
HP7475, HP7470, ATT 435
Printers
ThinkJet, LaserJet II
Sensors
See Appendix D or the Boonton Electronics Sensor Data Manual for detailed
specifications of Boonton Peak Power Sensors.
CE Mark
Boonton Electronics Corporation declares conformity of the Model 4400A
RF Peak Power Meter and the Model 4500A RF Peak Power
Meter/Analyzer to the following European Community Council (ECC)
regulations:
Directives: 89/336/EEC/93/68/EEC and 73/23/EEC/93/68/EEC
Standards: EN55011, EN50082-1, EN61010-1
Notes
1
Sensor dependent
2
Sensitives are decreased by a factor of two in the split-screen mode.
3
CW mode
4
CW mode, 0 to 40
O
C
5
Available with optional second channel
ADDITIONAL PRODUCTS AND SERVICES
AVAILABLE* FROM BOONTON ELECTRONICS
CORPORATION
Model 4530 series RF Peak Power Meter 10 kHz to 40 GHz
Model 4230A series RF Power Meter 10 kHz to 40 GHz
Model 9230 series RF Voltmeter 200
m to 300 V, 10 Hz to 2.5 GHz
Model 5230 series Universal RF Power Meter/Voltmeter 200
mV
to 300 V, 10 Hz to 100 GHz
Model 4300 RF Power Meter, multi-channel 10 kHz to 40 GHz
Model 92EA RF Millivoltmeter 200
mV to 300 V, 10 Hz to 1.2 GHz
Model 7200 Capacitance Meter 0 to 2,000 pF, 1 MHz, Analog
display
Model 72B Capacitance Meter 1 pF to 3,000 pF, 1 MHz, Analog
display
Model 8201 Modulation Analyzer 100 kHz to 2.5 GHz
Model 8701 VXI Modulation Analyzer 100 kHz to 2.5 GHz
Model 1121 Audio Analyzer 10 Hz to 140 kHz
Service and Support You Can Count On
Boonton Electronics backs all of its products with a
full range of test, repair, upgrade and calibration
services assuring that all your instrumentation
remains accurate, reliable and conforms to original
factory specifications.
Services include:
· Certified Repairs (NIST Traceable)
· Repair Warranty (Six Months, Materials and
Labor)
· Automatic Instrument/Software Upgrades*
· 10-day Turnaround
· Priority Service
· Flexible Service, Repair, and Calibration
Contracts
Contact our Customer Service Department at
(973) 386-9696 for details and pricing information.