Balanced with ground, Unbalanced, Gain – Atec AE-Techron-7796HC User Manual
Page 2: Residual noise, Slew rate, Display, control, status, Front panel led displays indicate, Lcd display, Soft touch switches for, User configurable
7796HC Datasheet
Information subject to change.
5/4//11
AC Specifications
PEAK OUTPUT
RMS OUTPUT
40mSec Pulse,
20% Duty Cycle
5 Minute,
100% Duty Cycle
1 Hour,
100% Duty Cycle
5 Minute,
100% Duty Cycle
1 Hour,
100% Duty Cycle
Ohms
Volts
Amps
Volts
Amps
Volts
Amps
Volts
Amps
Volts
Amps
Watts
2
79
39
79
39
79
39
56
28
56
28
1540
1
56
56
55
55
55
55
39
39
39
39
1512
0.5
53
106
52
104
50
100
37
74
35
71
2499
0.25
40
157
38
152
35
139
27
107
25
98
2432
Input Characteristics
Balanced with Ground:
Three terminal barrier block connector
20k ohm differential
Unbalanced:
BNC connector, 10k ohm single ended
Gain:
Voltage Mode: 20 volts/volt
Current Mode: 20 amperes/volt
Residual Noise:
DC – 30 kHz: Less than 75 microvolts
DC – 100 kHz: Less than 1 millivolt
Slew Rate:
41 volts per microsecond
Display, Control, Status
Front Panel
LED Displays indicate:
Ready, Standby and Fault conditions
in the output stage
LCD Display:
Lists type of fault condition and gives
suggested corrective action
Soft Touch Switches for:
Run (Enable), Stop, Reset
User Configurable:
LCD display can be configured for up
to four simultaneous displays reporting
one, two or all four of the following:
Voltage Peak, Voltage RMS, Current
Peak, and Current RMS
Physical Characteristics
Chassis:
All aluminum construction designed for
stand-alone or rack-mounted operation
with black chassis; the amplifier
occupies five EIA 19-inch-wide rack
units
Weight:
103 lbs. (46.7 kg)
AC Power:
Three-phase, 208 VAC ±10%, 47-60 Hz, 30A AC service.
NOTE: 400 VAC version not available.
Operating Temperature:
10°C to 50°C (50°F to 122°F), Maximum Output Power de-rated
above 30°C (86°F).)
Humidity:
70% or less, non-condensing