I NPUT SIGNALS: A highly linear Class A
design, these units will accept AM, FM,
SSB, CATV, Pulse and other modulations
with minimum distortion.

HARMONIC DISTORTION: All harmonics
are 25dB below the fundamental. Lower at
reduced power.

STABILITY: Unconditionally stable; units
will not oscillate for any conditions of load
and source impedances.

PROTECTION: Units will withstand more
than + 16dB overdrive (input signal of 1 V
r ms) for all output load conditions.

OUTPUT METERING: The output voltage
as well as power output into 50 Ohms is
monitored by a front panel meter.

POWER SUPPLY: Both the integral power
supply and cooling system are conserva-

tively designed to permit operation over a

wide range of temperature and AC line
conditions.