beautypg.com

Common characteristics, Mechanical specifications accessories – Atec B-K-8500 Series User Manual

Page 6

background image

6

w w w.bk prec ision.c om

DC Electronic Loads

Models 8500, 8502, 8510, 8512, 8514, 8518, 8520, 8522, 8524, 8526

Common characteristics

v061813

Standard

Power cord, user manual, installation CD with application software, RS232 to TTL serial converter cable IT-E131,

USB to TTL serial converter cable IT-E132

Optional

Rack mount kit IT-E151 for models 8500, 8502, 8510, 8512, 8514 and 8518 only

Model

Dimensions (W x H x D)

Weight

8500

8.46” x 3.46” x 14” (215 mm x 88 mm x 355 mm)

11.5 lb (5.2 kg)

8502

8.46” x 3.46” x 14” (215 mm x 88 mm x 355 mm)

11.5 lb (5.2 kg)

8510

16.9” x 3.46” x 14” (429 mm x 88 mm x 355 mm)

31 lb (14 kg)

8512

16.9” x 3.46” x 14” (429 mm x 88 mm x 355 mm)

31 lb (14 kg)

8514

16.9” x 3.46” x 14” (429 mm x 88 mm x 355 mm)

31 lb (14 kg)

8518

16.9” x 3.46” x 14” (429 mm x 88 mm x 355 mm)

31 lb (14 kg)

8520

17.48” x 7.09” x 21.22” (444 mm x 180 mm x 539 mm)

66 lb (30 kg)

8522

17.48” x 7.09” x 21.22” (444 mm x 180 mm x 539 mm)

66 lb (30 kg)

8524

17.48” x 14.06” x 21.22” (444 mm x 357 mm x 539 mm)

148 lb (67 kg)

8526

17.48” x 14.06” x 21.22” (444 mm x 357 mm x 539 mm)

148 lb (67 kg)

Parameter

Range

Accuracy

Resolution

CR Mode Regulation

(Input current ≥ FS 10%

Input voltage≥ FS 10%)

0.1 -10 Ω

±(1%+0.3% FS)

0.001 Ω

10-99 Ω

±(1%+0.3% FS)

0.01 Ω

100-999 Ω

±(1%+0.3% FS)

0. 1 Ω

1K-4 KΩ

±(1%+0.8% FS)

1 Ω

CW Mode Regulation

(Input current ≥ FS 10%

Input voltage≥ FS 10%)

0-100 W

±(1%+0.1% FS)

1 mW

100 W - max power

±(1%+0.1% FS)

100 mW

Power Measurement

(Input current ≥ FS 10%
Input voltage ≥ FS 10%)

0-100 W

±(1%+0.1% FS)

1 mW

100 W - max power

±(1%+0.1% FS)

100 mW

Other

Battery testing function

Input = 0.1 V – 120 V, Max measurement capacity = 999 Ah

Resolution = 10 mA, Timer range = 1-60000 sec

Transition mode

Range of Frequency 0.1 Hz-1 kHz, Frequency error rate 0.5%

* All 8500 series models, with the exception of models 8524 and 8526, can be configured for 110 V or 220 V operation via the AC line switch in the rear
panel. Base models 8524 and 8526 operate with 110 V only. For 220 V operation, order model 8524-220V or 8526-220V respectively. “-220V” denotes
220 V operation only and these models cannot be reconfigured for 110 V operation.

Mechanical specifications

Accessories

Power input

110 / 220 (see note below)* VAC ± 10%, 47 – 63 Hz

Operating temperature

32 ºF - 104 ºF (0 - 40 ºC)

Storage temperature

50 ºF - 140 ºF (10 - 60 ºC)

Humidity

≤ 95% relative humidity, non-condensing

Safety

EN61010-1:2001, EU Low Voltage Directive 73/23/EEC amended by 93/68/EEC

Electromagnetic compatibility

Meets EMC Directive 89/336/EEC amended by 93/68/EEC, EN50081-1, EN50082-1

One-Year Warranty