Model k576, Portable load bank, Specifications – Atec Avtron-K576 User Manual
Page 2: Outline drawing
LOAD CONNECTON
TERMINALS
SCREENED
AIR EXHAUST
LIFTING
HANDLES
(BOTH ENDS)
SCREENED
AIR INLET
(BOTH SIDES)
CONTROL
SWITCHES
CUSTOMER
CABLE ENTRY
(3.00 [76.00] DIA.)
28.00
[711.00]
27.00
[685.00]
24.00
[609.00]
3.50
[88.00]
3.50
[88.00]
4.00 [101.00]
All dimensions are in inches [millimeters]. Specifications subject to change without notice.
SPECIFICATIONS:
CONSTRUCTION: The load bank is contained in a rugged
aluminized steel enclosure, with two rigid and two lockable
swivel casters mounted at the corners, and four lifting handles
provided for simplified handling.
CONTROL POWER: Control power is derived from an exter-
nal 120 volt, single phase, 60 Hz power source. A line cord
is included with the load bank for quick disconnect.
BLOWER: A heavy duty, reliable, industrial blower is used
for cooling the resistive elements. This 1/4 HP device oper-
ates from the same 120 volt, single phase, 60 Hz power
source as the load bank control circuit.
RESISTIVE ELEMENTS: Made of a chromium
alloy, the resistive elements are specially
wound and continuously supported
in the cooling air stream. They are de-
signed to operate at one half of their
rated temperature rating for more
stable loading and longer life without the need for a cool
down period.
CONTROL PANEL: It includes a POWER ON-OFF switch,
a power status indicator light, an ON-OFF switch for each
load step, a MASTER LOAD ON-OFF switch for applying
or removing all selected load steps, and a BLOWER FAIL
indicator light.
PROTECTIVE FEATURES: The control circuit is fuse pro-
tected and the load circuit is disabled by a differential
pressure air switch if insufficient cooling air is detected.
WEIGHT: Approximately 160 lbs. [73 kg]
Model K576
Portable Load Bank
6255 Halle Drive • Cleveland, Ohio, U.S.A. 44125-4615 • 216.573.7600 • FAX 216.573.5953
www.avtronloadbank.com • [email protected]
Bulletin 273 • Rev. C
OUTLINE DRAWING:
K576 LOAD CAPACITY RATINGS:
Total Load Amps
Volts DC
Load Steps in Amps
500
52
25, 25, 50, 100, 100, 100, 100
500
52
2.5, 5, 5, 12.5, 25, 50, 100, 100, 100, 100
Quality System Certified to ISO 9001