beautypg.com

2011gc_en 135a – Atec Chroma-63113A User Manual

Page 2

background image

11-13

All specifications are subject to change without notice.

All specifications are subject to change without notice.

All specifications are subject to change without notice.

All specifications are subject to change without notice.

Programmable DC Electronic Load

Model 63110A/63113A

SPECIFICATIONS

Model

63110A (100Wx2)

63113A *3

Power

100W

300W

Current

0~0.6A

0~2A

0~5A

0~20A

Voltage *1

0~500V

0~300V

Min. Operating Voltage

6V@2A

4V@20A

LED Mode

Range

Operation Voltage: 0~100V/0~500V

R

d

Coefficient : 0.001~1

V

F

: 0~100V/0~500V

Current : 0~2A

R

d

: 1Ω~1kΩ/10Ω~10kΩ

Operating Voltage : 0~60V/0~300V

R

d

Coefficient : 0.001~1

V

F

: 0~60V/0~300V

LEDL @ CCH : 0~60V- 0~20A (R

d

: 0.05Ω~50Ω)

LEDL @ CCL : 0~60V- 0~5A (R

d

: 0.8Ω~800Ω)

LEDH @ CCL : 0~300V- 0~5A (R

d

: 4Ω~4kΩ)

Resolution *2

Vo : 4mV/20mV

Io : 0.1mA

R

d

Coefficient : 0.001

R

d

: 62.5µs/6.25µs

V

F

: 4mV/20mV

Vo : 1.2mV/6mV

Io : 100µA/400µA

R

d

Coefficient : 0.001

R

d

: 400µs / 25µS / 5µS

V

F

: 1.2mV/ 6mV

Constant Resistance Mode

Range

CRL : 3Ω~1kΩ (100W/100V)

CRH : 10Ω~10kΩ (100W/500V)

CRL @ CCH : 0.2Ω~200Ω (300W/60V)

CRL @ CCL : 0.8Ω~800Ω (300W/60V)

CRH @ CCL : 4Ω~4kΩ (300W/300V)

Resolution*2

CRL : 62.5µS

CRH : 6.25µS

CRL @ CCH : 100µS

CRL @ CCL : 25µS

CRH @ CCL : 5µS

Accuracy

1kΩ : 4mS+0.2%

10kΩ : 1mS+0.1%

200Ω : 0.2% (setting + range)
800Ω : 0.2% (setting + range)

4kΩ : 0.2% (setting + range)

Constant Voltage Mode
Range

0~500V

0~300V

Resolution

20mV

6mV

Accuracy

0.05% + 0.1%F.S.

0.05% + 0.1%F.S.

Constant Current Mode
Range

0~0.6A

0~2A

0~5A

0~20A

Resolution

12µA

40µA

100µA

400µA

Accuracy

0.1%+0.1% F.S.

0.1%+0.1% F.S.

0.1%±0.2% F.S.

Measurement Section
Voltage Read Back
Range

0~100V

0~500V

0~60V

0~300V

Resolution

2mV

10mV

1.2mV

6mV

Accuracy

0.025%+0.025% F.S.

0.025%+0.025% F.S.

Current Read Back
Range

0~0.6A

0~2A

0~5A

0~20A

Resolution

12µA

40µA

100µA

400µA

Accuracy

0.05%+0.05% F.S.

0.05%+0.05% F.S.

NOTE*1 : If the operating voltage exceeds 1.1 times of the rated voltage, it would cause permanent damage to the device.
NOTE*2 : S (siemens) is the SI unit of conductance, equal to one reciprocal ohm.
NOTE*3 : Call for availability