S p e c i f i ca t i o n s

DESCRIPTION

SPECIFICATION

POWER REQUIREMENTS

Internal Lead acid Gel Cell battery provides 8 hrs of continuous
operation. AC charging: (Std) 115/230 VAC 50/60 Hz ±10%.
(Opt) 100/200 VAC 50/60 Hz ±10%. (Opt) 12 VDC

VELOCITY

0.5 - 20 FPS [0.15 - 6.08 MPS]

OUTPUTS

4-20 mA, 600 Ohms max., isolated.

INDICATORS

Power, Signal Strength, Flow Analyzer, Fault, Over-range,
Read, Low Battery, Charge

DISPLAY

2 line x 20 character alphanumeric LCD (backlit). Digit height 0.2
inches [5 mm], 6 digit rate, 6 digit totalizer (resettable)

UNITS:

User configured

RATE U.S. [METRIC]

FPS, GPM, MGD [MPS, LPM, M

3

/hr]

TOTALIZER U.S. [METRIC]

Gallons [liters, M

3

]

AMBIENT CONDITIONS

-22 to 160°F [-30 to 70 °C], 0-95% relative
humidity, non-condensing.

ENCLOSURE

NEMA 4X, [IP-65] ABS with SS hardware. 11W x 17L x 8D inches
[279W x 432L x 203D mm]

NON-LINEARITY (ACCURACY)

±2% Full Scale

SENSITIVITY

0.4% of Full Scale

REPEATABILITY

±0.4% of Full Scale

RESPONSE TIME

5-50 seconds, user configured, to 90% of value,
step change in flow.

TRANSMITTER

TRANSDUCER

DESCRIPTION

SPECIFICATION

LIQUID REQUIREMENTS

25 ppm of 30 micron size* suspended solids or entrained gases (air).
*Less than this minimum will re q u i re transducer mount downstream
of a 90° elbow.

TRANSDUCER TO
TRANSMITTER DISTANCE

(Std) 20 feet [6.08 meters], retractable cord.

PIPE SIZES

(Std) 1 - 120 inches [25 - 3050 mm] Pipe I.D.
(Opt.) 0.25 - 1 inch [6 - 25 mm], Small Pipe Transducer

TEMPERATURE

(Std) -40° to 250°F [-40° to 121°C].
(Opt) -40° to 400°F [-40° to 204°C]

HOUSING MATERIAL

(Std) Aluminum, Ultem™ w/epoxy encapsulation
(High Temp) Vesped™, Aluminum

Portable Enhanced Doppler