Atec Cincinnati-Sub-Zero-Z Series User Manual
Page 9
24°C
85°C
24°C
-34°C -68°C
-18°C
-34°C
-40°C
-54°C
-68°C
-40°C
93°C
190°C
24°C 24°C
ZP-8-1.5-1-H/AC
8
15
18
25
38
50
8
25
10
15
ZP-8-2-2-H/AC
5
8
10
12
18
35
8
25
10
15
ZP-16-2-2-H/AC
8
10
12
18
25
28
10
30
10
20
ZP-16-3.5-3.5-SC/AC
6
8
11
17
23
25
10
30
10
20
ZP-16-6-6-SC/WC
4
6
7
10
15
15
10
25
6
12
ZP-32-2-2-H/AC
10
16
20
28
38
55
20
60
10
20
ZP-32-3.5-3.5-SC/AC
8
14
18
25
35
35
20
60
10
20
ZP-32-6-6-SC/WC
5
8
10
15
25
25
10
30
8
15
ZPS-32-10-10-SC/WC
4
6
7
10
15
15
7
20
6
10
ZPS-32-15-15-SC/WC
3
4
5
7
10
8
6
16
5
8
ZP-44-3.5-3.5-SC/AC
15
22
28
40
50
50
12
45
12
20
ZP-44-6-6-SC/WC
8
12
15
20
25
30
12
45
12
20
ZPS-44-10-10-SC/WC
5
7
8
12
18
15
8
20
7
10
ZPS-44-15-15-SC/WC
4
5
6
8
12
10
6
15
5
8
ZP-64-3.5-3.5-SC/AC
15
25
30
40
60
60
20
60
15
25
ZP-64-6-6-SC/WC
10
15
20
25
35
35
20
60
15
25
ZPS-64-10-10-SC/WC
6
8
9
15
22
20
10
25
8
12
ZPS-64-15-15-SC/WC
5
6
7
9
15
12
8
20
6
10
Cooling Performance
with Empty Chamber in Minutes from:
Heating Performance
with Empty Chamber in Minutes from:
-18°C
-34°C
-40°C
-54°C
-68°C 208/230V, 1 Phase 208/230V, 3 Phase 460V, 3 Phase
ZP-8-1.5-1-H/AC
-
-
650
450
200
50
35
-
ZP-8-2-2-H/AC
-
-
1200
900
600
70
55
-
ZP-16-2-2-H/AC
-
-
1800
1200
600
70
55
-
ZP-16-3.5-3.5-SC/AC
-
-
2000
1600
1000
-
70
-
ZP-16-6-6-SC/WC
-
-
3000
2400
1500
-
100
45
ZP-32-2-2-H/AC
-
-
1500
1100
600
70
55
-
ZP-32-3.5-3.5-SC/AC
-
-
2000
1600
1000
-
70
-
ZP-32-6-6-SC/WC
-
-
3000
2400
1500
-
100
45
ZPS-32-10-10-SC/WC
-
-
4500
3500
1700
-
-
70
ZPS-32-15-15-SC/WC
-
-
5500
4500
2500
-
-
90
ZP-44-3.5-3.5-SC/AC
-
-
1700
1300
700
-
70
-
ZP-44-6-6-SC/WC
-
-
2700
2100
1200
-
100
45
ZPS-44-10-10-SC/WC
-
-
4500
3500
2000
-
-
70
ZPS-44-15-15-SC/WC
-
-
5500
4500
3000
-
-
90
ZP-64-3.5-3.5-SC/AC
-
-
1500
1100
500
-
70
-
ZP-64-6-6-SC/WC
-
-
2500
2100
1000
-
100
45
ZPS-64-10-10-SC/WC
-
-
4500
3500
2000
-
-
70
ZPS-64-15-15-SC/WC
-
-
5500
4500
3000
-
-
90
Live Load Capacity
Watts
Electrical Power Requirements
Minimum Amp Service
Cascade -73°C to 190°C
Cincinnati Sub-Zero
Whether you need to do basic temperature cycling or
fast temperature cycling, the Z-Plus offers a variety
of sizes, temperature ranges and performance
Whether you need to do basic temperature cycling or fast temperature cycling,
the Z-Plus offers a variety of sizes, temperature ranges and performance
packages that meet your testing needs.