Atec EM-Test-VCS-500N8 User Manual
Page 2

DATA SHEET > VCS 500N8 > 20130627
TECHNICAL DETAILS
VCS 500N8 MODELS
VCS 500N8
8kV Surge Generator w/o. built-in
CDN; an external CDN is required
VCS 500N8.1
8kV Surge Generator with built-in
1ph CDN 250V / 16A
VCS 500N8.2
8kV Surge Generator with built-in
3ph CDN 3*440V / 16A
VCS 500N8.3
8kV Surge Generator with built-in
3-phase CDN 3*690V (L-L) / 32A
VCS 500N8.5
8kV Surge Generator with built-in
3-phase CDN 3*440V (L-L) / 32A
COMBINATION WAVE 1.2/50US - 8/20US
Voltage (o.c.)
250V - 8,000V ± 10%
Front time
1.2µs ± 30%
Time to half value
50µs ± 20%
Current (s.c.)
max. 4,000A ± 10%
Front time
8µs ± 20%
Time to half value
20µs ± 20%
Polarity
Positive/negative/alternating
Event counter
1 - 30,000 or endless
TRIGGER
Trigger of events
Automatic, manual, external
CRO trigger
5V trigger signal for oscilloscope
Synchronization
0° - 360°, resolution 1°
Repetition rate
9s - 999s, depending on the voltage
OUTPUT
Direct
Via HV connectors for external
coupling networks (Zi = 2ohm with
optional adapter IMN 2)
VCS 500N8.1
Built-in single phase coupler
AC: 250V/16A; 50/60Hz
DC: 250V/10A
VCS 500N8.2
Built-in 3-phase coupler
3 x 440VAC / 16A; 50/60Hz
DC: 250V/10A
VCS 500N8.5
Built-in 3-phase coupler
3 x 440VAC / 32A; 50/60Hz
DC: 250V/20A
VCS 500N8.3
Built-in 3-phase coupler
3 x 690VAC / 32A; 50/60Hz
DC: 400V/20A
Coupling mode
Line to line with 2ohm
Line(s) to PE with 12ohm
MEASUREMENTS
CRO Û-monitor
10Vp at 8,000V
CRO Î-monitor
10Vp at 4,000A
Peak voltage
8,000V in the LCD display
Peak current
4,000A in the LCD display
TEST ROUTINES
Quick Start
Immediate start, easy-to-use and
fast
User Test routines
Change Polarity after n pulses
Change voltage after n pulses
Standard Test
routines
As per IEC/EN 61000-4-5,
Level 1,000V - Level 4,000V
Manual Standard Test routine
Service
Service, setup, self test
INTERFACE
Optical interface
Opto link, 3 m cable
USB A connector
Parallel interface
IEEE 488, addresses 1 - 30
SAFETY
Safety circuit
Control input (24Vdc)
Warning lamp
Floating output contact
GENERAL DATA
Dimensions,
weight
VCS 500N8
19"/6HU, approx. 25kg
VCS 500N8.1
19"/6HU, approx. 28kg
VCS 500N8.2
19"/6HU, approx. 35kg
VCS 500N8.3
19"/9HU, approx. 55kg
VCS 500N8.5
19"/9HU, approx. 52kg
Supply voltage
115/230V +10/-15%
Fuses
2x2AT (230V) or 2x4AT (115V)
OPTIONS
iec.control 1
Remote control and documentation
software, including standard test
routines and reporting capabilities.
IMN 2
Impedance matching adapter to
match direkct output to 2ohm source
impedance
www.emtest.com
© EM TEST > PAGE 2/4