DATA SHEET > PFS 503N-series > 20120410
TECHNICAL DETAILS
PFS 503N SERIES MODEL CONFIGURATION
PFS 503N32
3x480V AC, max. 32A per phase
277V AC (L-N), 360V DC
PFS 503N63
3x480V AC, max. 63A per phase
277V AC (L-N), 360V DC
PFS 503N100
3x480V AC, max. 100A per phase
277V AC (L-N), 360V DC
PFS 503N32.1
3x690V AC, max. 32A per phase
400V AC (L-N), 600V DC
PFS 503N63.1
3x690V AC, max. 63A per phase
400V AC (L-N), 600V DC
PFS 503N100.1
3x690V AC, max. 100A per phase
400V AC (L-N), 600V DC
POWER SWITCHES
Three-phase application
Voltage (L-L)
3x480V AC resp. 3x690V AC
Frequency
50Hz/60Hz
Single phase application
Voltage (L-N)
277V AC resp. 400V AC
360V DC resp. 600V DC
Frequency
50Hz/60Hz and DC
Current AC/DC
Max. 32A (PFS 503N32/N32.1)
Max. 63A (PFS 503N63/N63.1)
Max. 100A (PFS 503N100/N100.1)
Peak current
PFS 503N32/N32.1:
Better than 500A
PFS 503N63/N63.1 and
PFS 503N100/N100.1:
Better than 1,000A as per
IEC 61000-4-34
Fall/rise time
Between 1us and 5us for abrupt
changes, generator loaded with
resistive load
Switches are electronically protected
against short-circuit
TRIGGERING
Automatic
Release of the events according to
the settings
Repetition rate
0.01s to 9,999s
Duration td
0.02ms to 9,999s
Manual
Release of a single event via function
key
External
Release of a single event by an
external trigger signal
Synchronization
0° to 360°, resolution 1°
OUTPUTS
3-phase
application
L1, L2, L3, N and PE on the rear panel
1-phase
application
L, N and PE on the front panel
MEASUREMENTS
CRO Trigger
+15V trigger signal for oscilloscope
CRO Î
Built-in current probe 10mV/A; max.
700A on each line
TEST ROUTINES
Quick Start
Immediate start, easy-to-use and
fast
Standard Test
routines
IEC 61000-4-11, Level 1 to Level 3
User Test routines
Customer specific routines
Change duration after n events
Change phase angle after n events
Asynchronous mode
Voltage variation
Service
Service routines, Set-up
INTERFACES
Serial
USB
Parallel
IEEE 488, addresses 1 to 30
Analog output
0 to 10 V DC to control an external
motor variac
GENERAL DATA
Dimensions
19"/6 HU
Weight
app. 28kg;
PFS 503N100/N100.1 app. 35kg
Supply voltage
115V/230V; +10/-15%
Fuses
2 x T 1A (230V) or 2 x T 2A (115V)
www.emtest.com
© EM TEST > PAGE 3/5