beautypg.com

Atec EM-Test-PFS-503N User Manual

Page 3

background image

DATA SHEET > PFS 503N-series > 20120410

TECHNICAL DETAILS

PFS 503N SERIES MODEL CONFIGURATION

PFS 503N32

3x480V AC, max. 32A per phase
277V AC (L-N), 360V DC

PFS 503N63

3x480V AC, max. 63A per phase
277V AC (L-N), 360V DC

PFS 503N100

3x480V AC, max. 100A per phase
277V AC (L-N), 360V DC

PFS 503N32.1

3x690V AC, max. 32A per phase
400V AC (L-N), 600V DC

PFS 503N63.1

3x690V AC, max. 63A per phase
400V AC (L-N), 600V DC

PFS 503N100.1

3x690V AC, max. 100A per phase
400V AC (L-N), 600V DC

POWER SWITCHES

Three-phase application

Voltage (L-L)

3x480V AC resp. 3x690V AC

Frequency

50Hz/60Hz

Single phase application

Voltage (L-N)

277V AC resp. 400V AC
360V DC resp. 600V DC

Frequency

50Hz/60Hz and DC

Current AC/DC

Max. 32A (PFS 503N32/N32.1)
Max. 63A (PFS 503N63/N63.1)
Max. 100A (PFS 503N100/N100.1)

Peak current

PFS 503N32/N32.1:
Better than 500A
PFS 503N63/N63.1 and
PFS 503N100/N100.1:
Better than 1,000A as per
IEC 61000-4-34

Fall/rise time

Between 1us and 5us for abrupt
changes, generator loaded with
resistive load

Switches are electronically protected
against short-circuit

TRIGGERING

Automatic

Release of the events according to
the settings

Repetition rate

0.01s to 9,999s

Duration td

0.02ms to 9,999s

Manual

Release of a single event via function
key

External

Release of a single event by an
external trigger signal

Synchronization

0° to 360°, resolution 1°

OUTPUTS

3-phase
application

L1, L2, L3, N and PE on the rear panel

1-phase
application

L, N and PE on the front panel

MEASUREMENTS

CRO Trigger

+15V trigger signal for oscilloscope

CRO Î

Built-in current probe 10mV/A; max.
700A on each line

TEST ROUTINES

Quick Start

Immediate start, easy-to-use and
fast

Standard Test
routines

IEC 61000-4-11, Level 1 to Level 3

User Test routines

Customer specific routines
Change duration after n events
Change phase angle after n events
Asynchronous mode
Voltage variation

Service

Service routines, Set-up

INTERFACES

Serial

USB

Parallel

IEEE 488, addresses 1 to 30

Analog output

0 to 10 V DC to control an external
motor variac

GENERAL DATA

Dimensions

19"/6 HU

Weight

app. 28kg;
PFS 503N100/N100.1 app. 35kg

Supply voltage

115V/230V; +10/-15%

Fuses

2 x T 1A (230V) or 2 x T 2A (115V)

www.emtest.com

© EM TEST > PAGE 3/5