beautypg.com

Atec EM-Test-ESD30N User Manual

Page 2

background image

DATA SHEET > ESD 30N > 20091019

TECHNICAL DETAILS

TEST LEVEL

Test voltage

200V - 30,000V ± 5% for contact
discharge

200V - 30,000V ± 5% for
air discharge

Resolution

100V steps

Holding time (AD)

More than 5s

MAINFRAME ESD 30N

HV power supply

Up to 30kV DC

Power supply

88V - 250V AC
12V - 18V DC

Battery

Approx. 1 hour operation;
Buffer battery is automatically
recharged when connected to AC
mains supply

Interface

USB to control the ESD generator
and to download pre-programmed
test routines from esd.control

DISCHARGE UNIT P 30N

Hand held discharge unit

Controls

2 function keys and one control
wheel

Display

Graphic LCD display

Test level

200V to 30,000V

Polarity

Positive, negative; selectable

Discharge mode

Air or Contact discharge, selectable

Discharge tip

Point and ball type

Indicators

Integrated sensor to measure
temperature and rel. humidity

TRIGGER

Single pulse

Release of a single pulse

Multiple pulses

Continuous discharge up to 20Hz

Counter

0 - 9,999 for discharge pre-selection

OUTPUT

Contact Discharge
Pulse

As per EN/IEC 61000-4-2;
150pF/330ohm

Rise time

As per EN/IEC 61000-4-2 Ed.2
0.8ns +/- 25%

First peak current
value

As per EN/IEC 61000-4-2 Ed.2
7.5A ± 15% @2kV
15A ± 15% @4kV
22.5A ± 15% @6kV
30A ± 15% @8kV

Current value at
30ns

As per EN/IEC 61000-4-2 Ed.2
4.0A ± 30% @2kV
8.0A ± 30% @4kV
12.0A ± 30% @6kV
16.0A ± 30% @8kV

Current value at
60ns

As per EN/IEC 61000-4-2 Ed.2
2.0A ± 30% @2kV
4.0A ± 30% @4kV
6.0A ± 30% @6kV
8.0A ± 30% @8kV

GENERAL

Weight

Approx. 5.1kg (ESD 30N control unit)

Weight

Approx. 1,250g (P 30N discharge
gun)

Supply voltage

AC: 88V - 264V, 50/60Hz
DC: 11V - 16VDC

Fuses

2x 0.5A T

ACCESSORIES (INCLUDED)

Discharge tips for AD and CD

Grounding lead 2m

Test certificate and instruction
manual

www.emtest.com

© EM TEST > PAGE 2/4