DATA SHEET > Transient Emission Set > 20130814

TECHNICAL DETAILS

BS 200N100 - ELECTRONIC SWITCH

SPECIFICATION

Operation voltage

Max. 60V DC

Operation current

Max. 100A continuous

Peak voltage

Max. 1,000V

Inrush current

Max. 400A for 200ms

Voltage drop

< 1.2V at 100A
< 0.2V at 25A

Overvoltage
protection

By varistors

Overload
protection

Short-circuit protected
Reverse-polarity protected

SWITCH CHARACTERISTICS

Switching time

300ns +/- 20% into test load
50uH/0.6ohm

On/Off time

10ms to 500ms, continuously
selectable via potentiometer

Operation mode

Indicatied by LED

TRIGGER

Manual

Manual trigger of a single event

Auto

Automatic trigger with min. 0.1Hz to
max. 1Hz repetition, continuously
selectable by potentiometer

External In

Enternal trigger, negative going
edge 0V, BNC input 10V

MEASUREMENT

Voltage monitor

BNC output; divider 1:200 +/-5%

Trigger Out

BNC output; negative going edge 0V

GENERAL DATA

Dimensions,
weight

90mm x 125mm x 120mm (LxWxH)
(without connecting sockets)
approx. 1.3kg

Supply voltage

24V DC via mains supply adapter

AN 200N100 - ARTIFICIAL NETWORK

TECHNICAL DATA

as per

ISO 7637-2, CISPR 25, ISO 11452-4
and CISPR 16-1-2, switchable

Frequency range

0.1 to 125MHz

Operation voltage

1,000V DC/250V AC up to 1kHz

Operation current

Max. 100A AC/DC continuous

Inrush current

Max. 400A for 200ms

Impedance

5uH // 50ohm
for details see diagrams on page 2

Insertion loss

less than 3dB DUT to receiver output

Inductance

5uH +/-10% air-core coil

Coupling
capacitor

0.1uF

CONNECTIONS

Power supply/DUT
connection

High-current connectors up to 100A
4mm safety lab connectors up to 32A

Test output

BNC-connection

GENERAL DATA

Dimensions

318 x 126 x 122 mm (L x W x H)
(without connecting sockets)

Weight

approx. 2.8kg

www.emtest.com