LISN / PLISN

2

22

22

Test Site Hardware

Applications

Model 3816/2 LISN

LISNs and PLISNs, also known as artificial

mains, are a valuable tool for EMC

engineers. In addition to their usual

function, LISNs can be used as a diagnostic

aid to evaluate EME designs. A paper

entitled,

Using a LISN as an Electronic

System EMC Diagnostic Tool, by David

Staggs, describes how LISNs, normally

used for conducted measurement, can be

used to anticipate and reduce radiated

emissions. Mr. Staggs’ paper notes that

conducted resonances often have

correspondence to frequencies in the

radiated profile. By identifying and

reducing a conducted resonance, a

corresponding resonance in the radiated

profile is often reduced as well. Contact ETS

Sales for a copy of this paper.

MODEL

TEST TYPE

FCC-15

VDE 0871

VDE 0876

EN55022

3810/2

CE

CE

CE

CE

& 3816/2

Physical Specifications

MODEL

WIDTH

DEPTH

HEIGHT

WEIGHT

3810/2

22.2 cm

38.1 cm

15.2 cm

4.9 kg

& 3816/2

8.7 in

15.0 in

6.0 in

10.7 lb

MODEL

LINES

FREQUENCY

POWER

MAXIMUM

MAXIMUM

NETWORK

POWER IN

POWER OUT

PLUS

RANGE

SOURCE

CURRENT

VOLTAGE

INDUCTANCE

CONNECTOR

CONNECTOR

GROUND

FREQUENCY

IMPEDANCE

Electrical Specifications

Operational Features

MODEL

MANUAL

ARTIFICIAL

MANUAL

MANUAL

REMOTE

SWITCHED

HAND

SWITCHED

SWITCHED

SWITCHED

EARTHLINE CHOKE

HIGH PASS FILTER

TEST PORTS

TEST PORTS

3810/2

"

"

"

3816/2

"

"

"

"

"

3810/2 NM

2

9kHz - 30 MHz

60 Hz

10 A

125 VAC Line to Ground

50

µ

H / 250

µ

H

IEC power inlet

NEMA

®

SH

50 Hz

10 A

250 VAC Line to Ground

50

with customer

SCHUKO

®

BS

50 Hz

10 A

250 VAC Line to Ground

specified plug

British

3816/2 NM

2

9kHz - 30 MHz

60 Hz

15 A

125 VAC Line to Ground

50

µ

H / 250

µ

H

Integral cord

NEMA

®

SH

50 Hz

16 A

250 VAC Line to Ground

50

with

SCHUKO

®

BS

50 Hz

16 A

250 VAC Line to Ground

NEMA

®

plug

British

Model 3810/2, 3816/2

Information presented is subject to change as product enhancements are made. Contact ETS Sales Department for current specifications.

Information presented is subject to change as product enhancements are made. Contact ETS Sales Department for current specifications.

Information presented is subject to change as product enhancements are made. Contact ETS Sales Department for current specifications.

Information presented is subject to change as product enhancements are made. Contact ETS Sales Department for current specifications.

Information presented is subject to change as product enhancements are made. Contact ETS Sales Department for current specifications.

3/00 - 2k S © 2000 ETS-EMCO REV A

3/00 - 2k S © 2000 ETS-EMCO REV A

3/00 - 2k S © 2000 ETS-EMCO REV A

3/00 - 2k S © 2000 ETS-EMCO REV A

3/00 - 2k S © 2000 ETS-EMCO REV A

USA:

Tel +1.512.835.4684
Fax +1.512.835.4729

FINLAND:

Tel +358.2.8383.300
Fax +358.2.8651.233

ONLINE:

[email protected]
http://www.emctest.com