beautypg.com

Atec EM-Test-CDN_M-Type User Manual

Page 4

background image

DATA SHEET > CDNs > 20120612

TECHNICAL DETAILS

32A M-TYPE CDN MODELS

CDN-M1/32A

For Earth conductor
- AE: 4mm safety lab connectors
- EUT: 4mm safety lab connectors
- Voltage/current max. 240V/32A
- Frequency 150kHz - 230MHz

CDN-M1/32A S1

For Earth conductor
- AE: 4mm safety lab connectors
- EUT: 4mm safety lab connectors
- Voltage/current max. 1,000V/32A
- Frequency 150kHz - 230MHz

CDN-M2N/32A

For 2 AC/DC supply lines (L & N)
- AE: 4mm safety lab connectors
- EUT: 4mm safety lab connectors
- Voltage/current max. 240V/32A
- Frequency 150kHz - 230MHz

CDN-M2/32A S1

For 2 AC/DC supply lines (L & N)
- AE: 4mm safety lab connectors
- EUT: 4mm safety lab connectors
- Voltage/current max. 1,000V/32A
- Frequency 150kHz - 80 (230) MHz

CDN-M2/32A S2

For 2 AC/DC supply lines (L & N)
- AE: 4mm safety lab connectors
- EUT: 4mm safety lab connectors
- Voltage/current max. 750V/32A
- Frequency 150kHz - 80 (230) MHz

CDN-M3N/32A

For 3 AC/DC supply lines (L/N/PE)
- AE: 4mm safety lab connectors
- EUT: 4mm safety lab connectors
- Voltage/current max. 240V/32A
- Frequency 150kHz - 230MHz

CDN-M3/32A S2

For 3 AC/DC supply lines (L1/L2/L3)
- AE: 4mm safety lab connectors
- EUT: 4mm safety lab connectors
- Voltage/current max. 3x400V/32A
- Frequency 150kHz - 80(230)MHz

CDN-M3/32A S3

For 3 AC/DC supply lines (L/N/PE)
- AE: 4mm safety lab connectors
- EUT: 4mm safety lab connectors
- Voltage/current max. 750V/32A
- Frequency 150kHz - 80MHz

...

32A M-TYPE CDN MODELS (CONTINUATION)

CDN-M4-PE/32A

For 4 AC/DC supply lines
(L1/L2/L3/PE)
- AE: 4mm safety lab connectors
- EUT: 4mm safety lab connectors
- Voltage/current max. 3x400V/32A
- Frequency 150kHz - 80MHz

CDN-M4-PE/32A
S1

For 4 AC/DC supply lines
(L1/L2/L3/PE)
- AE: 4mm safety lab connectors
- EUT: 4mm safety lab connectors
- Voltage/current max. 3x750V/32A
- Frequency 150kHz - 80MHz

CDN-M4-N/32A

For 4 AC/DC supply lines
(L1/L2/L3/N)
- AE: 4mm safety lab connectors
- EUT: 4mm safety lab connectors
- Voltage/current max. 3x400V/32A
- Frequency 150kHz - 80MHz

CDN-M4-N/32A S1

For 4 AC/DC supply lines
(L1/L2/L3/N)
- AE: 4mm safety lab connectors
- EUT: 4mm safety lab connectors
- Voltage/current max. 3x750V/32A
- Frequency 150kHz - 80MHz

CDN-M5/32A

For 5 AC/DC supply lines
(L1/L2/L3/N/PE)
- AE: 4mm safety lab connectors
- EUT: 4mm safety lab connectors
- Voltage/current max. 3x400V/32A
- Frequency 150kHz - 80MHz

50A / 75A M-TYPE CDN MODELS

CDN-M2/50A

For 2 AC/DC supply lines (L & N)
- AE: 6mm safety lab connectors
- EUT: 6mm safety lab connectors
- Voltage/current max. 240V/50A
- Frequency 150kHz - 80MHz

CDN-M2/75A

For 2 AC/DC supply lines (L & N)
- AE: 6mm safety lab connectors
- EUT: 6mm safety lab connectors
- Voltage/current max. 240V/75A
- Frequency 150kHz - 80MHz

Special M-type CDN's on request

www.emtest.com

© EM TEST > PAGE 4/8