Atec Agilent-11691D User Manual
Page 3
11691D
11692D
Frequency range
2 to 18 GHz
2 to 18 GHz
Minimum directivity
2 to 8 GHz: 30 dB
2 to18 GHz: 30 dB
8 to 18 GHz: 26 dB
1
8 to 18 GHz: 26 dB
1
Maximum primary line SWR
2 to 12.4 GHz: 1.3
2 to 12.4 GHz: 1.3
12.4 to 18 GHz: 1.40
12.4 to 18 GHz: 1.40
Maximum auxiliary port(s) SWR
1.3
1.3
Nominal coupling (dB)
20
20
Maximum coupling variation with frequency (dB)
±1 dB
±l dB
2
Tracking auxiliary arms
*
±0.7 dB
3
*
Maximum primary line residual loss
< 2 dB
< 1.5 dB
Primary line power
50
Ω average
50
Ω average
Handling capability
250
Ω peak
250
Ω peak
Net weight
1.93 kg (4 1b, 4 oz)
2.72 kg (6 1b, 0 oz)
Dimensions
404.8 mm (15-15/16 in) L
404.8 mm (15-15/16 in) L
133.4 mm (5-1/4 in) H
133.4 mm (5-1/4 in) H
42.9 mm (1-11/16 in)W
42.9 mm (1 -11/16 in)W
11691D connector
Primary line
Option
Input/output
Auxiliary arms
Standard
APC-7/APC-7
N(f)
11692D connector options
Primary line
Auxiliary arms
Option
Input/output
Incident/reflection
11692D-005
N(f)/APC-7
N(f)/N(f)
11692D-001
N(f)/N(f)
N(f)/N(f)
11692D-002
N(f)/N(m)
N(f)/N(f)
11692D-003
N(f)/APC-7
APC-7/APC-7
11692D-004
APC-7/APC-7
APC-7/APC-7
Connectors
The APC-7 and type-N connectors are stainless steel
designed for durability. The type-N connectors con-
form to MIL-C-39012 or MIL-C-71.
3
1. 24 dB with type-N connector on the INPUT PORT (11691D) or TEST PORT (11692D).
2. Incident to test port.
3. With the test port shorted and not including source match ripple.
* Typical tracking between 11691D and 11692D is ±0.07 dB.
Figure 2. Directivity specifications.
Figure 3. Typical coupling curve.