Hyamp, Ii specifications – Atec Associated-Research-5030DT User Manual
Page 3
HYAMP
®
II Specifications
INPUT
115/230V selectable, ± 15% variation
47 - 63 Hz
FUSE
115 VAC, 230VAC -- 10A fast acting 250VAC
OUTPUT
Current: AC 3 - 31 Amps, 0.01 Amp/step
ADJUSTMENT
Regulation: ± (2% of Setting + 0.02A)
Voltage: AC 3 - 8 Volts, 0.1 Volt/step
OUTPUT
50/60 Hz selectable
FREQUENCY
HIGH TRIP
0 - 600 m
Ω for 3 - 12 Amps, 1 mΩ /step
RANGE
0 - 150 m
Ω for 3 - 31 Amps, 1 mΩ/step
Accuracy: ± (2% of setting + 2 m
Ω)
LOW TRIP
0 - 600 m
Ω for 3 - 12 Amps, 1 mΩ /step
RANGE
0 - 150 m
Ω for 3 - 31 Amps, 1 mΩ/step
Accuracy: ± (2% of setting + 2 m
Ω)
MILLIOHM
Max. Offset Capability: 100 m
Ω , 1 mΩ /step
OFFSET
Accuracy: ± (2% of setting + 2 m
Ω)
CURRENT
4 digits
DISPLAY
Range: 0 - 31 Amps
Resolution: 0.01 Amp/step
Accuracy: ± (3% of Reading + 0.03 A)
OHMMETER
3 digits
DISPLAY
Range: 0 - 600 m
Ω
Resolution: 1 m
Ω/step
Accuracy: ± (2% of Reading + 2m
Ω)
TIMER
4 digits
DISPLAY
Range: 0 - 999.9 seconds
Resolution: 0.1 seconds /step
Accuracy: ± (0.1% of Reading + 0.05 seconds)
DWELL
0 and 0.5 – 999.9 seconds, 0.1 second/step
TIMER
“0” for continuous running
Accuracy: ± (0.01% of Setting + 0.02 seconds)
REMOTE
CONTROL
The following input and output signals are
(PLC)
provided through two 9 pin D type connectors:
1. Inputs: test, reset and withstand processing.
2. Remote recall of memory program #1, #2 & #3.
3. Outputs: pass, fail, test in process, reset out,
and start out.
MEMORY
Allows storage of up to 10 different test programs.
SECURITY
Password lockout capability to avoid unauthorized
access to test set-up program.
LINE CORD
Detachable 7 ft. (2.13 m) power cable terminated
in a three prong grounding plug.
TERMINATIONS
5 ft. (1.52 m) high current and return leads with clips.
MECHANICAL
Bench or rack mount (2U height) with tilt up
front feet.
Dimensions: (w x h x d) 17 x 3.5 x 16.5 inches
(432 x 88 x 419 mm)
Weight: 27.6 lbs. (12.5 kgs)
ENVIRONMENTAL Operating Temperature: 32° - 113° F (0° - 45°C)
Relative Humidity: 0 to 95%
CALIBRATION
Traceable to National Institute of Standards and
Technology (NIST). Calibration controlled by
software. Adjustments are made through front
panel keypad in a restricted access calibration mode.
Calibration information stored in non-volatile memory.
INTERNATIONAL VERSIONS
HYAMP
®
II shown with HypotPLUS
®
II and
interconnecting receptacle box for testing products
terminated in a line cord. Also shown are the standard
rack mount handles.
HYAMP
®
II and HypotPLUS
®
II together offer a true
semi-automated test system. The system can be
configured to test Ground Bond first and then to advance
to the Dielectric Withstand test. The system can also be
set up to perform both tests simultaneously for greater
time savings and increased throughput.
HYAMP
®
II includes rear panel high current and return connections and remote
control connections to make it easier to build into a rack mount system.
High resolution LCD clearly indicates setup
parameters and test results.
Options:
1-01
HYAMP
®
II to HypotPLUS
®
II Interface Kit,
includes receptacle box.