Model 6470-B quickly checks ground rod resistance with its Connect - Press - Read approach

Features

2- and 4-Wire Bond Resistance/Continuity

Measurement (DC Resistance) with automatic

polarity reversal

3-Pole (3-Point) Fall-of-Potential measurement

with manual or automatic frequency selection

4-Pole (4-Point) Fall-of-Potential measurement

for very low resistance measurements with

manual and automatic frequency selection and

automatic lead compensation

4-Pole (4-Point) Soil Resistivity measurement

with automatic calculation of Rho (r) and user

selection of the Wenner or Schlumberger test

method

3-Pole (3-Point) Earth Coupling measurement

Manual and automatic frequency scan from

40 to 513Hz for optimum test accuracy in

electrically noisy environments

Selectable test voltage of 16 or 32V up to

250mA of test current

Auto-off power management

Automatic recognition of all electrode

connections and their resistance value

Stores up to 512 complete test results in

internal memory

Optically isolated USB communication

Remote set up and operation of all

measurements using DataView

®

software

supplied

Automatic report generation

Rechargeable NiMH batteries from wall charger

or vehicle power

Rugged dustproof and rainproof field case –

IP54 rated in closed position

Grounding standards IEC 61557 parts 4 and 5

compliant

Includes DataView

®

software for data storage,

real-time display, analysis, report generation and

system configuration

applications

3-Point measurements of resistance to

ground of ground rods and grids. 3-Point

measurements are generally used when the

electrode or grid can be easily disconnected.

4-Point tests or soil resistivity

measurements. Locating areas of lowest

soil resistivity is essential for achieving an

economical grounding installation.

Touch and step potential testing

measurements. These tests are

recommended when the ground cannot be

disconnected, where ground faults are highly

likely to occur, or when the “footprint” of

grounded equipment (the outline of the part

of equipment in contact with the earth) is

comparable to the size of the ground

to be tested.

2- or 4-Wire tests for continuity

tests on bonding or on grounding systems.

This test is a DC resistive test using 250mA

or more and is used to check bonding of all

connection points on the ground system.

Earth coupling measurement and display.

Used to estimate the influence of two earth

resistance systems that are not connected to

each other.

2 www.aemc.com

Technical Assistance (800) 343-1391

The Digital Ground Resistance Tester Model 6470-B is a portable

measurement instrument designed to measure Ground Resistance, Soil

Resistivity (two methods – Wenner and Schlumberger), Bonding Resistance

(DC Resistance 2-Wire and 4-Wire Kelvin sensing) and Earth Coupling

resistance. This direct reading tester measures from 0.01 to 99.99kΩ and is

auto-ranging, automatically seeking out the optimum measurement range and

test current.
Easy-to-use – simply connect the leads, select the test mode, press Start and

read the results. Up to 512 test results can be stored in internal memory for

later recall to the display or downloaded to a PC via DataView

®

software.

The large LCD is easy-to-read and indicates ground electrode resistance,

test voltage, current and frequency as well as individual electrode resistance,

battery status and more.
The Model 6470-B is Cat IV rated to 50V and is over voltage protected to

more than 250VAC against accidental connection to live circuits. The voltage

is also displayed on screen. In the event of a system fault, the Model 6470-B

can withstand 250VAC.
Additional features of the Model 6470-B include a heavy-duty field case

sealed against dust and water when closed (the test button is also sealed

against the elements); manual and automatic test frequency selection from 40

to 513Hz; user selectable 3-Pole (3-Point) Fall of Potential or 4-Pole (4-Point)

Soil Resistivity test methods and user selectable 2-Wire or 4-Wire Bond

Resistance test method.
The Model 6470-B is powered by 9.6V, 3.5 Ah NiMH rechargeable batteries.

An external recharger powered from 120/230V 50/60Hz is included and

provides for testing while recharging. The Model 6470-B can also be vehicle

powered from an optional 12V battery adapter.
The Ground Resistance Tester Model 6470-B is rugged, easy-to-use

and ideal for maintenance crews performing numerous tests. It exceeds

mechanical and safety specifications for shock, vibration and drop tests per

IEC standards. The adjustable test frequency provides for rejection of high

levels of interference, allowing it to be used under difficult conditions such as

high stray currents that normally affect accuracy.