Specifications – Atec AEMC-4610 User Manual
Page 3
Specifications
ELECTRICAL
Ranges (Auto-Ranging 0 to 2000Ω)
20Ω
200Ω
2000Ω
Measurement
0.00 to 19.99Ω
20.0 to 199.9Ω
200 to 1999Ω
Resolution
10mΩ
100mΩ
1Ω
Open Voltage
≤42V peak
Resistance Measurement
128Hz square wave
Frequency
Test Current
10mA
1mA
0.1mA
Accuracy
±2% of Reading ± 1ct
±2% of Reading ± 1ct
±3% of Reading ± 3cts
Auxiliary Electrode Influence
Range
20Ω
3kΩ
50kΩ
Current Circuit
200Ω
30kΩ
50kΩ
Voltage Circuit
2000Ω
50kΩ
50kΩ
Interference
Model 4610 rejects high levels of interference voltage (DC, 50 to 60Hz, harmonics):
DC voltage in series with X: 20V; AC voltage in series with Y: 13V peak;
AC voltage in series with Z: 32V peak
Response Time
Approximately 6 seconds for a stabilized measurement
Withstanding Voltage
250V
AC
with spikes of 3000V
AC
or 1000V
DC
Power Source
Eight 1.5V “AA” batteries; Alkaline recommended; “LO BAT” indication on LCD
Battery Life
1800 15-second measurements
Fuse Protection
High breaking capacity 0.1A, >250V, 0.25 x 1.25"
MECHANICAL
Display
7-segment LCD, 0.71" (18mm) high (3
1
/
2
digit); 2000-counts;
LCD also indicates overrange, test lead shorts and lead reversals
Connection
Color-coded terminals accept spade lugs with min. gap of 6mm or
standard 4mm banana jacks
LED Indication
Three LEDs indicate high input noise, high auxiliary rod resistance,
open leads, blown fuse
Operating Temperature
14° to 131°F (-10° to 55°C), 0 to 90% RH
Storage Temperature
-40° to 158°F (-40° to 70°C), 0 to 90% RH with batteries removed
Dimensions
8.7 x 5.4 x 5.9" (220 x 136 x 150mm)
Weight
2.9 lbs (1.3kg)
Case
Heavy-duty ABS
Colors
Case: safety yellow; Front panel: gray
Mechanical Shock
IEC 68-2-27
Vibration Test
IEC 68-2-6
6
Drop Test
IEC 68-2-32
Dielectric Test
3kV, 50/60Hz, 1 min. between four interconnected measuring terminals
and any external metal ground
Environmental
O-ring sealed against dust
and water to IP50 (Protection Index)
Electrostatic
IEC 801-2
Electromagnetic
IEC 801-3
Electric Shock
IEC 801-5
SAFETY
Rating
EN 61010-1, Cat. III, Pollution Degree 2, 42V
Agency Approval
Emission (EN 50081-1)
Immunity (EN 50082-1)
Double Insulation
Yes
CE Mark
Yes
Accuracies and specifications are given for an ambient temperature of 23°C ± 3°K, RH of 45 to 55%, battery power at 8V, auxiliary
resistance at the measurement terminals < 200Ω, no stray voltage and a magnetic field from 0 to 40Å/m.
Test Equipment Depot - 800.517.8431 - 99 Washington Street Mel