Surge and Hipot in one Tester
Call Baker Today
Features:
Options:
Specifications:*
With a Digital Winding Tester from Baker, you
can perform surge and hipot tests, as well as digitize and
store test data for future use.
Surge testing detects faults in both inter-turn
winding and phase-to-phase insulation systems. Using
advanced analog-to-digital conversion hardware, the “D”
series captures the surge test waveform, remembers it,
displays it indefinitely, and prints it to the included ink jet
printer. This surge waveform storage capability can be
applied to other motors besides simple induction motors.
The “D” Series can be used to test all the rotating fields of
a synchronous motor by storing the waveform from a
surge test on one coil, and comparing that waveform to a
waveform from every other coil. The Digital Winding
Tester can also be used on DC armatures or fields. The
resulting waveform can then be compared to all other bar-
to-bar or span tests to detect a winding fault.
DC hipot testing detects faults in
groundwall/earth insulation, and also provides insulation
resistance and polarization index measurement.
Test results from up to 10 motors in the field can
be stored, retrieved, printed, and uploaded to a desktop
program for file management and analysis. Each of these
10 motor records has its own memory location. Each
location can store up to three surge wave patterns plus DC
hipot test voltage and current. The Digital Winding Tester
can operate on its own in the field, and then transfer the
test data to a computer running Baker’s Motor Test
Acquisition (MTA) software for further analysis. MTA for
Windows provides database capabilities, waveform
comparison, report generation, printouts, and other
functions that turn test data into usable information. All
options are easily accessed with on-screen prompts.
At Baker, we never stop looking for ways to improve your
competitive edge with innovative test solutions.
Storage of test data for up to10 motors
3 Surge Wave Patterns with Amplitude and
Timebase
Surge Test Peak Voltage Amplitude
DC Hipot Voltage
DC Hipot Leakage Current
Insulation Resistance
Baker’s QRR reliability high voltage design
Zero start interlock for tester High Voltage Output
Bright, sharp, digital 5-inch display
safety warning indicator
Hipot Over-Current safety warning indicator
Input Source
operator safety disable and
warning indicator
Test leads insulated to 45 KV rating
Test Lead Select Switch with All Leads Grounded
operator safety position
Parallel printer and PC interface
FS-12 Footswitch for Push to Test allows hands-free
operation
RAS-12 Roll A round Stand for convenient height of
operation and movement
PP-30D 30KV Surge/DC Hipot Power Pack
Windows 95, 98, & NT Compatible Motor Test
Management A nalysis Software
Compatible ink jet printer
!
,
,
,
,
,
!
!
!
!
!
!
!
!
!
!
!
!
!
!
Leads Energized
Open Ground
Surge Test
12KV
6KV
DC High Potential Test:
Phsyical Characteristics
Maximum Output Voltage
12000 volts
6000 volts
Maximum Output Current
800 amps
380 amps
Maximum Pulse Energy
2.88 joules
0.72 joules
Maximum Output Voltage
12000 volts
6000 volts
Maximum Output Current
1000 Amps 1000 Amps
Overcurrent Trip
10/100/1000 Amps
Current Resolution
1/10/100 Amps per division
Weight (kilograms/pounds)
22.7/50
21.5/46
Dimensions
19x8x23 in. (WxHxD)
Power Input
120 VAC/60 Hz or
220 VAC/50 Hz
µ
µ
µ
µ
*Data Subject to change without notice. Printed in U SA 10/99.
Whether you’re trouble shooting, manufacturing, or
rebuilding, Baker’
s digital tester consistently detects
faulty windings that other testers miss.
Baker Instrument Company
PO Box 587 Fort Collins, CO 80522
(970) 282-1200 (800)752-8272
FAX: (970) 282-1010
www.bakerinst.com
⋅
⋅