The F6300 and F6150 combination can easily test all high-burden electromechanical
relays. The burden presented by electromechanical relay-based protection schemes are
very high, requiring high-power current sources to drive the necessary current. When
used together, the F6300 and F6150 can deliver three currents up to 90 A, 3-phase
continuous at 450 VA or 180 A for 1.5 seconds at 675 VA.
Three voltage sources and one current source of 450 VA are provided by the F6150,
while two 450 VA current sources are provided by the F6300.
AC Amplitude Accuracy at 50/60 Hz
Current Sources
From 20° to 30° C: < 0.02% typical or
< 0.09%
Guaranteed typical 0.02% of reading
Distortion and noise at 50/60 Hz output
(10 Hz-2 kHz Bandwidth)
Current Sources
Total Harmonic Distortion (THD) < 0.02%
typical, < 0.1% guaranteed
Phase Angle:
range:
0 to + 359.9° (lead) /
0 to – 359.9° (lag)
Accuracy:
±0.25° at 50/60 Hz for
current sources
resolution:
0.1°
Frequency:
Bandwidth:
dc to 3 kHz at full
power for transient play-
back
range:
dc; ac from 0.1 Hz to
2 kHz at full power
continuous load
resolution:
0.001 Hz
Accuracy:
0.05 ppm
Typical
1.5 ppm
20° to 30° C
10 ppm
0° to 50° C
toget
Her
we
P
ower
t
He
worl
D
Doble Engineering Company
85 Walnut Street
Watertown, MA 02472 USA
tel +1 617 926 4900
fax +1 617 926 0528
MKT-SL-F6300-03/08
Doble is certified iSo 9001:2000
Doble is an eSCo technologies Company
F6300 technical Specifications and Source
Configurations
output Power Continuous
2 x 450 VA sources
6 x 150 VA sources
output Power transient for 1.5 seconds
2 x 675 VA sources
6 x 225 VA sources
2 x 450 VA Sources
ranges (resolutions)
AC Current
1.5 seconds transient 15A (0.001 A), 45,
90, 180 A rms (0.01 A)
Continuous 7.5 (0.001 A), 22.5 A, 45,
90 A rms (0.01 A)
DC Current
1.5 seconds Transient 10 (0.001 A), 30,
60, 120 A dc (0.01A)
Continuous 5 15 (0.001 A), 30, 60 A dc
(0.001 A)
6 x 150 VA Sources
ranges (resolutions)
AC Current
1.5 seconds Transient 15 (0.001 A), 30,
60 A rms (0.01 A)
Continuous 7.5, 15 A (0.001 A), 30 A rms
(0.01 A)
DC Current
1.5 seconds Transient 10 (0.001 A), 20,
40 A dc (0.01 A)
Continuous 5 A (0.001 A), 10, 20 A dc
(0.01 A)
Physical Specifications
Dimensions:
15 x 9.5 x 18 inches
38 x 24 x 45.7 cm
weight:
35.4 lb / 16.1 kg
line Power Supply: 105–132 V or 210–264
V, 47–63 Hz
interfaces:
RS 232 and Ethernet
control to PC
operating
temperature:
0° to 50° C
32° to 122° F
Storage
temperature:
-25°to 70° C
-13° to 158° F
Humidity: