beautypg.com

Specifications, Displays – Atec AEMC-DTR-8500 User Manual

Page 3

background image

Digital Transformer Ratiometer DTR

®

Model 8500 (pdf)

08/02

Technical Assistance (800) 343-1391

www.aemc.com

3 of 5

MODEL

DTR

®

8500

ELECTRICAL

Ratio Range

Auto-Ranging, 0.8000 to 1500.0:1

Accuracy*

Ratio <10 to 1: ±0.2% of Reading

Ratio

10 to 1000 to 1: ±0.1% of Reading

Ratio >1000 to 1: ±0.2% of Reading

Excitation Signal

PT/VT Mode: 44Vrms maximum

CT Mode: 0 to 1A Auto Level, 0.1 to 5Vrms

Excitation Current Display

Range: 0 to 1000mA; Accuracy: ±2% of Reading ± 2mA

Excitation Frequency

70Hz

Display

LCD Character, 20 x 2, large format, LED backlight, day/night visible

Measurement Method

In accordance with ANSI/IEEE C57.12.90

Power Source

Dual operation; rechargeable NiCD battery & 115/230V, 50/60Hz line supply.

DTR® may be changed from 115/230V by internal switch at any time. Units available with factory presetting of 115 or 230V.

Batteries

12V, 5 x 2 NiCD packs, 1300mAH, Panasonic P-130SCR or equivalent

Battery Life

Up to 10 hrs continuous operation. May be used while recharging. Low battery LCD indication.

Charging Time

14 hrs typical, C/10 rate

Line Fuse

115V: 1.0A, 5 x 20mm, slow acting
230V: 0.5A, 5 x 20mm, slow acting

Displayed Measurements

Turns ratio; RMS excitation current; polarity

Displayed Messages

Incorrect lead connections; H/X reversal (accidental step-up misconnection);

Short (excess excitation current); Open circuits; Circuit continuity & low battery

MECHANICAL

Connections

Cannon

®

XLR connectors and large color-coded industrial clips

Leads

15 ft, H x X color-coded, in carrying bag

Display

Dual line alpha-numeric 3.875 x 0.875" with contrast adjustment and backlight

Operating Temperature

32° to 122°F (0° to 50°C), 0 to 90% RH (without condensation)

Case

Heavy duty structural polypropylene (yellow)

Dimensions

13 x 12 x 6" (330 x 305 x 152mm)

Weight

14 lb (6.4kg)

Specifications

Simple concise operation - clear informative data displays

Selected mode indication

Automatically self-calibrates with every use

Continuity test option selected

Indicates possible shorts in windings

Automatically detects and displays improper
cable connections

Displays ratio and excitation current