Digital Micro-Ohmmeter Model 5600 (pdf)

03/03

Technical Assistance (800) 343-1391

www.aemc.com

2 of 5

Specifications

ELECTRICAL

Range

2000µ

20m

200m

2000m

20

200

Display

1999

19.99

199.9

1999

19.99

199.9

Resolution

10µ

100µ

1m

10m

100m

Test Current

10A

1A

1A

100mA

10mA

10mA

Accuracy

0.25% typical

0.25% typical

0.25% typical

0.25% typical

0.25% typical

0.25% typical

0.5% max ± 2cts 0.5% max ± 1ct 0.5% max ± 1ct 0.5% max ± 1ct 0.5% max ± 1ct 0.5% max ± 1ct

Power Source

Rechargeable 6V, 7Ah NiCD battery; built-in 110V/220V (47 to 450Hz) charger;

automatic shutoff after 4 minutes non-use

Battery Life

200µ

range: 200 to 300 8-second measurements

20-200m

ranges: 900 30-second measurements (approx.)

2000m

, 20-200

ranges: 5000 30-second measurements (approx.)

Operating Voltage

4.5 to 7V

DC

Recharge Time

14 hours from full discharge (approx.)

MECHANICAL

Display

2000-count, 7-segment LED

Connection

Terminals accept 4mm banana plugs or 6mm (min) spade lugs

Operating Temperature

14° to 131°F (-10° to 55°C)

Storage Temperature

-4° to 131°F (-20° to 55°C)

Dimensions

15.35 x 10.24 x 9.84" (390 x 260 x 250mm)

Weight

17 lbs 10 oz (8kg)

Case

Fiberglass-charged polycarbonate with handle and removable lid,

watertight to IP534 (lid closed), IP520 (lid open)

Colors

Safety-yellow case, gray faceplate

SAFETY

Safety Ratings

Electrical: IEC 38, Supply voltage, Electromagnetic: IEC 801-2, Electrostatic discharge;

EN 61010, 300V, Cat. II, IEC 801-3, Electromagnetic fields; IEC 801-5, Electrical shocks,

Mechanical/environmental: IEC 529, Protection Index (IP); IEC 68.2.6, Vibration;

IEC 68.2.27, Shocks; IEC 68-2-29, Shake IEC 68.2.31, Knock over;

IEC 68.2.32, Drop test, Case Material: UL94

Overload Input Protection

380Vrms

Fuses

Two high-interrupting capacity 8A 380V, 1

1

/

4

x

1

/

4"

CE Mark

Yes

Features

Four-terminal Kelvin resistance
measurement

Up to 10A test current

0.25% basic accuracy

1m

resolution

Direct reading, easy to operate

Six selectable ranges

Reverse polarity switch

Overload and input fuse protection

Automatic decimal point and zero

Rechargeable NiCD battery with
integral charger (110/220V)

Rugged field case for industrial
applications

Applications

Contact resistance of breakers
and switches

Wire to terminal connections

Winding resistance of motors
and transformers

Resistance on electric motors

Aircraft and rail bonds

Grounding connections

Battery strap measurements

Test Equipment Depot www.testequipmentdepot.com
99 Washington Street 800-517-8431
Melrose, MA 02176-6024 781-665-0780 FAX